812942a7fd81c647.tex
1: \begin{abstract}
2: 
3: We extend the orbital-dependent electron tunneling model implemented within the three-dimensional (3D) Wentzel-Kramers-Brillouin
4: (WKB) atom-superposition approach for simulating scanning tunneling microscopy (STM) by including arbitrary tip orientations.
5: The orientation of the tip is characterized by a local coordinate system centered on the tip apex atom obtained by a rotation
6: with respect to the sample coordinate system. The rotation is described by the Euler angles.
7: Applying our method, we highlight the role of the real-space shape of the electron orbitals involved in the tunneling,
8: and analyze the convergence and the orbital contributions of the tunneling current above the W(110) surface depending
9: on the orientation of a model tungsten tip. We also simulate STM images at constant-current condition, and find that their quality
10: depends very much on the tip orientation. Some orientations result in protrusions on the images that do not occur above W atoms.
11: The presence of such apparent atom positions makes it difficult to identify the exact position of surface atoms. It is suggested
12: that this tip orientation effect should be considered at the evaluation of experimental STM images on other surfaces as well.
13: The presented computationally efficient tunneling model could prove to be useful for obtaining more information on the local tip
14: geometry and orientation by comparing STM experiments to a large number of simulations with systematically varied
15: tip orientations.
16: 
17: \end{abstract}
18: