1: \begin{abstract}
2: 
3: \noindent
4: {\bf Abstract} \\
5: {\bf Purpose:} 
6: Statistical iterative reconstruction is expected to improve the image quality of megavoltage computed tomography (MVCT).
7: However, one of the challenges of iterative reconstruction is its large computational cost. 
8: The purpose of this work is to develop a fast iterative reconstruction algorithm by combining several iterative techniques and by optimizing reconstruction parameters.
9: \\
10: {\bf Methods:} 
11: Megavolt projection data was acquired from a TomoTherapy system and reconstructed using our statistical iterative reconstruction.
12: Total variation was used as the regularization term and the weight of the regularization term was determined by evaluating signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and visual assessment of spatial resolution using Gammex and Cheese phantoms.
13: Gradient decent with an adaptive convergence parameter, ordered subset expectation maximization (OSEM), and CPU/GPU parallelization were applied in order to accelerate the present reconstruction algorithm.
14: \\
15: {\bf Results:} 
16: The SNR and CNR of the iterative reconstruction were several times better than that of filtered back projection (FBP).
17: The GPU parallelization code combined with the OSEM algorithm reconstructed an image several hundred times faster than a CPU calculation.
18: With 500 iterations, which provided good convergence, our method produced a 512$\times$512 pixel image within a few seconds.
19: The image quality of the present algorithm was much better than that of FBP for patient data.
20: \\
21: {\bf Conclusion:} 
22: An image from the iterative reconstruction in TomoTherapy can be obtained within few seconds by fine-tuning the parameters.
23: The iterative reconstruction with GPU was fast enough for clinical use, and largely improve the MVCT images.
24: 