1: % Template article for preprint document class `elsart'
2: % SP 2001/01/05
3:
4: \documentclass{elsart4}
5:
6: % Use the option doublespacing or reviewcopy to obtain double line spacing
7: \usepackage{graphics}
8: \usepackage{graphicx}
9: \usepackage{epsfig}
10: \usepackage{amssymb}
11:
12: \begin{document}
13:
14: \begin{frontmatter}
15:
16: \title{Measurement of mesoscopic High-$T_c$ superconductors using Si mechanical micro-oscillators}
17:
18: \author{M. Dolz , D. Antonio, H. Pastoriza}
19: \address{Centro At\'omico Bariloche, Comisi\'on Nacional de Energ\'{\i}a At\'omica and CONICET, R8402AGP S.
20: C. de Bariloche, Argentina}
21:
22: \begin{abstract}
23:
24: In a superconducting mesoscopic sample, with dimensions comparable
25: to the London penetration depth, some properties are qualitatively
26: different to those found in the bulk material. These properties
27: include magnetization, vortex dynamics and ordering of the vortex
28: lattice. In order to detect the small signals produced by this
29: kind of samples, new instruments designed for the microscale are
30: needed. In this work we use micromechanical oscillators to study
31: the magnetic properties of a Bi$_2$Sr$_2$CaCu$_2$O$_{8 + \delta}$
32: disk with a diameter of $13.5$ microns and a thickness of $2.5$
33: microns. The discussion of our results is based on the existence
34: and contribution of inter and intra layer currents.
35: \end{abstract}
36:
37: \begin{keyword}
38: MEMs \sep mesoscopic \sep high $T_c$
39:
40: \PACS 85.85.+j \sep 74.78.Na \sep 74.72.Hs
41: \end{keyword}
42: \end{frontmatter}
43:
44: % main text
45: \section{Introduction}
46: \label{}
47:
48: The study of the vortex physics in mesoscopic samples \cite{Aksyuk98,Chan01} is difficult
49: due to the need of instruments sensible enough to detect their signals. Sensitive
50: instruments such as SQUIDs are not the best option because they are not designed to
51: measure microscopic samples. The use of mechanical oscillators as magnetometers is not a
52: new idea, they have been used successfully for this application for some time
53: \cite{Kleiman85}. Our approach for studying mesoscopic high $T_c$ samples is to use
54: silicon micro-oscillators (following the work of \cite{Bolle99}) which have a torsional
55: mode with a resonant frequency $\nu _r \approx 45$ kHz and a quality factor $Q > 10^4$ at
56: low temperatures. This instrument integrates high sensitivity and reduced size with a
57: small signal loss, which is an important factor in the measurement of micron sized
58: samples.
59: \begin{figure}[t]\begin{center}
60: \includegraphics[width=\linewidth]{dolzFig1.eps}
61: \caption{Scanning electron micrograph of a high-$Q$ mechanical
62: oscillator with a BSCCO disk with a diameter of $13.5$ microns and
63: a thickness of $2.5$ microns. The sample was glued by means of
64: micro-pipettes and micro-manipulators.} \label{oscillator}
65: \end{center}\end{figure}
66:
67:
68: In this work we present the response of a micro-oscillator with a
69: Bi$_2$Sr$_2$CaCu$_2$O$_{8 + \delta}$ (BSCCO) disk mounted on top
70: of it, in the presence of an external magnetic field $H$. The
71: system (oscillator and sample) is shown in Fig. \ref{oscillator}.
72:
73: \section{Experimental details}
74: \label{}
75:
76: The mechanical micro-oscillator was manufactured at MEMSCAP \cite{Memscap} following the
77: MUMPS specifications. It consists of a central plate connected to two serpentine springs
78: which are anchored to the substrate. Below the plate two separate electrodes carry the
79: electrical signals. The plate is electrically grounded and harmonically driven by one of
80: the electrodes. The other electrode is used to detect the amplitude and phase of the
81: mechanical oscillations capacitively. The plate and the detection electrode form a
82: capacitor of $\approx 10$ fF. The motion of the plate produces a variation in the
83: capacitance $\delta C < 1$ fF. A bias voltage $V_b = 1.6$ V is held constant in the
84: capacitor and the current, proportional to $\delta C$ is measured by means of a
85: transimpedance amplifier and a lockin amplifier. This method diminishes the effect of the
86: parasitic capacitances because $V_b$ is constant. A sketch of the circuit is shown in
87: Fig. \ref{circuit}. From the Lorentzian fit of the amplitude vs. frequency curve, $\nu_r$
88: and $Q$ are derived.
89: \begin{figure}[t]\begin{center}
90: \includegraphics[width=\linewidth]{dolzFig2.eps}
91: \caption{System under study. The plate is driven by a sinusoidal
92: voltage. The displacement is capacitively detected with a
93: Current-Voltage Converter and a Lock-in Amplifier.}
94: \label{circuit}
95: \end{center}\end{figure}
96:
97: The resonant frequency depends on the springs constant $k$ and on
98: the system's moment of inertia $I$:
99: \begin{equation}
100: \nu_r = \frac{1}{2 \pi} \sqrt{\frac{k}{I}} .\label{fundamental}
101: \end{equation}
102:
103:
104: After the sample is glued to the oscillator, the system's moment of inertia is modified.
105: In our case, the sample is a single crystal BSCCO disk fabricated by lithographic
106: techniques and ion milling. The frequency variation was $\Delta \nu_r = 868$ Hz in
107: agreement with calculations (Fig. \ref{momentoinercia}).
108:
109: On the other hand, $\nu_r$ is also modified by variations in the
110: effective $k$ of the system. If the sample is magnetic, an
111: external magnetic field $H$ produces an additional torque
112: \begin{equation}
113: \overrightarrow{\tau}=(\overrightarrow{M} \times
114: \overrightarrow{H})V = MHV \sin \theta,
115: \end{equation}
116: where $M$ is the magnetization, $V$ is the sample 's volume and
117: $\theta$ is the angle between $\overrightarrow{M}$ and
118: $\overrightarrow{H}$. For small $\theta$
119: \begin{equation}
120: \tau=MHV \theta =k_s \theta.
121: \end{equation}
122:
123: The effective $k_e$ is obtained by adding $k_s$ to the spring
124: constant $k$. As a consequence, the resonant frequency increases
125: (decreases) if this torque is restoring (not restoring). The size,
126: geometry and anisotropy of the sample play an important role in
127: the magnitude and direction of its magnetization $M$. For example,
128: in a spherically symmetrical sample which is in the Meissner
129: state, $M$ remains antiparallel to $H$ during the whole period of
130: oscillation and the magnetic torque is zero ($k_s = 0$).
131: \begin{figure}[t]\begin{center}
132: \includegraphics[width=\linewidth]{dolzFig3.eps}
133: \caption{Response of the oscillator with and without sample. When the sample is mounted
134: on top of the oscillator the system moment of inertia increases and the resonant
135: frequency decreases $868$ Hz.} \label{momentoinercia}
136: \end{center}\end{figure}
137: \begin{figure}[t]\begin{center}
138: \includegraphics[width=\linewidth]{dolzFig4.eps}
139: \caption{Different behavior of the system when is applied an
140: external magnetic field. Currents in the layers of the sample are
141: depicted as a coil perpendicular to the plate and currents between
142: layers as a coil parallel to it} \label{coils}
143: \end{center}\end{figure}
144:
145: A more complete analysis of the system response can be made by
146: supposing a constant current flowing in a coil placed on the
147: oscillator in the presence of $H$. The coil carries the original
148: current plus any current induced by the tilt of the oscillator and
149: generated by Lenz's Law. In this way, a change in the angle
150: between the coil and the magnetic field produces a change in the
151: induced current and therefore in the total current flowing in the
152: coil. In Fig. \ref{coils}.a and Fig. \ref{coils}.b we sketch the
153: case where $H$ and the coil are perpendicular to the plate. The
154: original current in the coil generates a magnetic moment $m$ that
155: interacts with $H$ exerting an additional torque, which is
156: restoring (not restoring) when $m$ and $H$ are parallel
157: (anti-parallel). The induced current in the coil produced by the
158: tilt of the oscillator is proportional to $1 - \cos \theta$. On
159: the other hand, when the coil is parallel to the plate and
160: perpendicular to $H$ as in Fig \ref{coils}.c the original $static$
161: current produces a change in the angle of equilibrium $\theta _0$.
162: However, the change in $k_e$ produced by this current is
163: negligible if $\theta _0$ is small as in this case. The current
164: induced by the alternating tilt of the oscillator produces a
165: restoring torque proportional to $\sin \theta$. Finally, when $H$
166: is parallel to the oscillator the torque is restoring (not
167: restoring) if $m$ and $H$ are parallel (anti-parallel). If $m$ and
168: $H$ are perpendicular the current induced by the alternating tilt
169: of the oscillator always produces a restoring torque.
170:
171:
172: The sample (BSCCO) has a layered structure. On mounting the disk,
173: the Cu-O layers ($ab$ planes) are parallel to the oscillator.
174: Following the previous description, currents in the layers can be
175: associated with a coil perpendicular to the oscillator and
176: currents between layers with a coil parallel to it.
177:
178: \section{Results}
179: \label{}
180:
181: We did ZFC (zero field cooling) and FC (field cooling)
182: measurements. The difference $\Delta \nu _r$ between $\nu _r$
183: measured with and without an applied $H$ reflects the magnetic
184: response of the sample, eliminating any intrinsic effect in the
185: oscillator produced by changes in temperature. When an external
186: magnetic field is applied perpendicular to the $ab$ planes of the
187: sample, Meissner currents appear. These currents screen $H$
188: causing a non-restitutive torque (the intra layers current behaves
189: as in Fig. \ref{coils}.a). In this case, when the sample is in the
190: vortex state, $H$ penetrates the BSCCO forming pancake vortices
191: (PVs), and PVs in different layers are coupled weakly via
192: Josephson vortices (JVs). In Fig. \ref{perpendicular} we show the
193: measured $\Delta \nu_r vs. T$ data with $H=245$ Oe. $\Delta \nu
194: _r$ is always negative. When the temperature increases, the sample
195: becomes less diamagnetic and the magnitude of $\Delta \nu _r$
196: decreases. This is due to the entering of vortex in the sample. If
197: $H$ is parallel to the sample and to the oscillator $\Delta \nu
198: _r$ is always positive (Fig. \ref{parallel}). This is because the
199: thickness of the sample ($2.5$ microns) is smaller than the
200: penetration length in the $c$ direction ($30$ microns
201: approximately) and the magnetic moment of the JVs is negligible .
202: The only currents present in the sample are the Meissner ones,
203: that shield the alternating perpendicular $H$.
204: \begin{figure}[t]\begin{center}
205: \includegraphics[width=\linewidth]{dolzFig5.eps}
206: \caption{Temperature dependence of the normalized resonant frequency for ZFC-FC
207: measurements with external magnetic field ($H=245$ Oe) perpendicular to the plate and to
208: the $ab$ planes of the sample. $\Delta \nu_r$ is always negative.} \label{perpendicular}
209: \end{center}\end{figure}
210: \begin{figure}[t]\begin{center}
211: \includegraphics[width=\linewidth]{dolzFig6.eps}
212: \caption{Temperature dependence of the normalized resonant frequency for ZFC-FC
213: measurements with external magnetic field ($H=245$ Oe) parallel to the plate and to the
214: $ab$ planes of the sample. $\Delta \nu _r$ is always positive.} \label{parallel}
215: \end{center}\end{figure}
216: \section{Discussion and Conclusion}
217: \label{}
218:
219: In the first case, when $H$ is perpendicular to the layers of the sample, $m$ is
220: proportional to $1 - \cos \theta$ (as we already said in the previous section). The
221: maximum deflection of the oscillator depends on the width of the plate and the minimum
222: distance between the plate and the electrode before {\em snap-down} takes place. This
223: phenomenon consist in the collapse of the plate with the bottom electrode and it happens
224: when the deflection reaches a third of the equilibrium distance between them
225: \cite{microsystem}. In our case the maximum possible $\theta$ is $\approx 1.5$ degrees
226: giving a maximum change in $m$ of $0.035$ $\%$. On the other hand, when $H$ is parallel
227: to the layers $m$ is induced by the tilt of the oscillator (perpendicularly to the planes
228: $ab$ of the sample) and is proportional to $\sin \theta$.
229:
230:
231: It is well-known \cite{Kes90} that in BSCCO $2D$ samples, the
232: phase transition to the vortex state depends on the component of
233: $H$ perpendicular to the $ab$ planes of the sample
234: ($H_{c\parallel}$) and not on the component parallel to them.
235: Considering an error of $0.4$ Hz in the measurement of $\nu_r$ and
236: from the curves of Fig. \ref{perpendicular} we obtain $T_c (H_{c
237: \parallel}=245 Oe) = 78.7 \pm 0.7$ K. Due to the importance of
238: pinning, in the ZFC measurement $\nu_r$ is smaller than in the FC
239: measurement at low temperatures. When the temperature increases
240: these two curves become closer, and for $T > 46.4 \pm 0.7$ K the
241: behavior of the system is reversible. On the other hand, when $H$
242: is applied parallel to the sample (Fig. \ref{parallel}) the
243: measurements are almost reversible in all the range of
244: temperatures. In order to generate PVs, it is necessary to reach
245: the critical angle for which the perpendicular component of $H$
246: equals $H_{c1}$. The maximum component of $H$ perpendicular to the
247: $ab$ planes (appearing when the oscillator tilts) is of $6.5$ Oe
248: and, based on the observed reversibility, we can say that $H_{c1}$
249: is not reached.
250:
251: These Si mechanical micro-oscillators are very sensitive magnetometers, suitable to study
252: mesoscopic high $T_c$ samples. The change in the resonant frequency ($\Delta \nu _r$) can
253: be positive or negative, depending on factors such as sample size, geometry and
254: anisotropy. These factors determine how the currents and magnetic moments are generated
255: in the sample.
256: \begin{thebibliography}{00}
257:
258: \bibitem{Aksyuk98} V. Aksyuk, F. F. Balakirev, G. S. Boebinger, P. L. Gammel, R. C. Haddon,
259: D. J. Bishop, Science 280 (1998) 720.
260: \bibitem{Chan01} H. B. Chan, V. A. Aksyuk, R. N. Kleiman, D. J. Bishop, F.Capasso,
261: Science 291 (2001) 1941.
262: \bibitem{Kleiman85} R. N. Kleiman, G. K. Kaminsky, J. D. Reppy, R. Pindak, D. J. Bishop, Rev. Sci. Instrum.
263: 56 (1985)2088-2091.
264: \bibitem{Bolle99} C. A. Bolle, V. Aksyuk, F. Pardo, P. L. Gammel, E. Zeldov, E. Bucher, R. Boie, D. J. Bishop,
265: D. R. Nelson, Nature 399 (1999) 43-46 .
266: \bibitem{Memscap} MEMSCAP Inc. ,Durham, NC 27703, USA. http://www.memscap.com
267: \bibitem{microsystem} S. D. Senturia, Microsystem Design, Kluwer Academic Publishers, Norwel, 2001, Chapter 6.
268: \bibitem{Kes90} P. H. Kes, J. Aarts, V. M. Vinokur, C. J. van der Beek, Phys. Rev. Lett. 64 (1990) 1063-1066.
269:
270:
271: \end{thebibliography}
272:
273: \end{document}
274: