1: %\documentstyle[12pt,epsfig,rotate]{article}
2: \documentstyle[]{IEEEtran}
3: \def\figurename{\large Figure}
4: \def\abstractname{\large Abstract}
5: %\def\tablename{\large Table}
6: %\pagestyle{empty}
7:
8: %\textwidth=166mm
9: %\textheight=238mm
10: %\oddsidemargin=-4.4mm
11: %\topmargin=-0.4mm
12: %\headheight=0mm
13: %\headsep=0mm
14:
15: % A useful Journal macro
16: \def\Journal#1#2#3#4{{#1} {\bf #2}, #3 (#4)}
17:
18: % Some useful journal names
19: \def\NCA{\em Nuovo Cimento}
20: \def\NIM{\em Nucl. Instrum. Methods}
21: \def\NIMA{{\em Nucl. Instrum. Methods} A}
22: \def\NPB{{\em Nucl. Phys.} B}
23: \def\PLB{{\em Phys. Lett.} B}
24: \def\PRL{\em Phys. Rev. Lett.}
25: \def\PRD{{\em Phys. Rev.} D}
26: \def\ZPC{{\em Z. Phys.} C}
27:
28: \newcommand{\ra}{\rightarrow}
29: \newcommand{\aoh}{\mbox{$ Ar/CO_2/CH_4 $}}
30: \newcommand{\afh}{\mbox{$ Ar/CF_4/CH_4 $}}
31: \newcommand{\afo}{\mbox{$ Ar/CF_4/CO_2 $}}
32:
33:
34: \begin{document}
35:
36:
37: \begin{titlepage}
38:
39: \pagebreak
40:
41: \vspace*{0.1cm}
42: \begin{center}
43: {\huge Institute of Theoretical }
44: \end{center}
45: \begin{center}
46: {\huge and Experimental Physics }
47: \end{center}
48: \begin{center}
49: \vspace{0.5cm}
50: {\huge Preprint 43-00 }
51: \end{center}
52: \vspace{3.0cm}
53: \begin{center}
54: {\large \bf M.Danilov, L.Laptin, I.Tichomirov, M.Titov, Yu.Zaitsev}
55: \end{center}
56:
57: \begin{center}
58: \vspace{2.cm}
59: {\large\bf Aging tests of the proportional wire chambers}
60: \end{center}
61: \begin{center}
62: %\vspace{1.0cm}
63: {\large\bf using $\afh$(74:20:6), $\afh$(67:30:3)}
64: \end{center}
65: \begin{center}
66: %\vspace{1.0cm}
67: {\large\bf and $\afo$(65:30:5) mixtures}
68: \end{center}
69: \begin{center}
70: %\vspace{1.0cm}
71: {\large\bf for the HERA-B Muon Detector}
72: \end{center}
73:
74: \vspace{7.5cm}
75:
76: \begin{center}
77: {\large\bf Moscow 2000}
78: \end{center}
79:
80: \end{titlepage}
81:
82: \newpage
83:
84: %\vspace*{7.5cm}
85:
86: \begin{abstract}
87: \large
88:
89: The Muon Detector of the HERA-B experiment at DESY is a gaseous
90: detector that provides muon identification in a high-rate hadronic
91: environment.
92: We present our studies on the properties of several fast gases,
93: $\afh$ (74:20:6), $\afh$ (67:30:3) and $\afo$ (65:30:5),
94: which have been found to fulfill muon detection requirements.
95:
96: The severe radiation environment of the HERA-B experiment leads to the maximum
97: charge deposit on a wire, within the muon detector, of 200 mC/cm per year.
98: For operation in such an environment, the main criteria for the choice of gas
99: turned out to be stability against aging.
100: An overview of aging results from
101: laboratory setups and experimental detectors for binary and ternary
102: mixtures of $Ar$, $CH_4$, $CF_4$ and $CO_2$ is presented and
103: the relevance of the various aging results is discussed.
104: Since it is not clear how to extrapolate aging results from small
105: to large areas of irradiation, the lifetime of
106: aluminum proportional chambers was studied under various conditions.
107: In this paper we provide evidence
108: that aging results depend not only upon the
109: total collected charge.
110: It was found that the aging rate for irradiation with $Fe^{55}$
111: $X$-rays and 100~MeV $\alpha$-particles may differ by more than
112: two orders of magnitude.
113:
114: \end{abstract}
115: \large
116: \clearpage
117:
118: \pagenumbering{arabic}
119: \setcounter{page}{1}
120:
121: \section {Introduction.}
122:
123: The HERA-B experiment is a hadronic B-factory at DESY,
124: operating presently under LHC-like conditions,
125: five years before startup of LHC.
126: The muon detection system in HERA-B is made up of three different types
127: of gas proportional chambers: tube, pad and pixel~\cite{Proposal,TDR}.
128: The readout of the chambers is based on the ASD-8
129: amplifier shaper discriminator chip developed by the University
130: of Pennsylvania~\cite{electronics}.
131: Strong restrictions on the gas choice are imposed by
132: the harsh operating conditions.
133: In addition to the high radiation load, resulting in an
134: accumulated charge on a wire of up to 200 mC/cm per year, the
135: muon chambers have to withstand the presence of heavily
136: ionizing particles, neutrons, and low energy gammas.
137: The first level trigger requires high hit efficiency and
138: fast signal collection within the 96~ns time interval
139: between two consecutive bunch crossings.
140:
141: In section 2, the requirements and limitations of the choice
142: of gases for the muon system are explained and the chamber
143: characteristics studied with several fast $Ar/CF_4$-based mixtures
144: are discussed.
145: %However, the main criteria for the choice of the gas
146: %turned out to be the stability against the aging.
147: The overview of aging results from
148: laboratory setups and experimental detectors for binary
149: and ternary mixtures of $Ar$, $CH_4$, $CO_2$ and $CF_4$ is
150: presented in section 3.
151: Since it is not clear how to extrapolate aging results
152: from laboratory setups, when irradiating a small region of the wire,
153: to large areas of irradiation with hadronic particles,
154: we have studied aging properties
155: of aluminum proportional chambers operated with $\afh$ and $\afo$
156: mixtures with $Fe^{55}$ and $Ru^{106}$ sources and in
157: 100~MeV $\alpha$-beam.
158: The results of these aging tests performed in a variety of conditions
159: are summarized in sections 4 and 5.
160:
161: %Nowdays, two large area tube chambers
162: %are being irradiated in the HERA-B high-rate environment.
163: %In this paper we provide an evidence,
164: %that aging results depend not only from the total
165: %collected charge, but, in addition,
166: %could be also affected by
167: %the mode of operation and size of the irradiation area.
168:
169:
170: \section{ Selection of fast gas mixtures.}
171:
172: Large area gaseous detectors operated under
173: high intensity particle fluxes impose
174: new requirements for gas selection.
175: The HERA-B muon system, with a total gas volume of 8~$m^3$,
176: puts rather stringent constraints
177: on the gaseous medium to be used: extremely low aging,
178: high sparkproofness, good electrical properties (high drift
179: velocity $v_d$, convenient operating electric field E/p),
180: good chemical properties (non-flammable, non-poisonous).
181: Since it is necessary to replenish part of the gas to avoid
182: contamination by air, the cost of the component gases is also an
183: important issue for gas selection.
184:
185: For a minimum working voltage, noble gases are usually chosen
186: since they require the lowest electric field intensities
187: for avalanche formation.
188: However, photons limit the attainable gas amplification
189: in the $Ar$-operated counters to $\sim 10^{4}$
190: without encountering a permanent discharge induced
191: by the photon-feedback mechanism taking place at the cathode.
192: This problem can be remedied by the addition of gases,
193: such as hydrocarbons, alcohols, $CO_2$, $H_2 O$, $N H_3$.
194: These molecular additives act like quenchers and improve
195: the operational stability
196: of the counter by absorption of ultraviolet photons from the
197: multiplication process, de-excitation of $Ar$ atoms~\cite{scint},
198: and by the charge transfer
199: mechanism prevent the neutralization of argon ions at the cathode,
200: thus reducing electron emission
201: through predissociation of quench gas ions~\cite{start,co2}.
202: Some of the polyatomic gases will also effectively increase
203: the total ionization by the Penning effect.
204:
205: Moreover, in pure $Ar$ the electron drift velocity is $\sim 30$
206: times lower than in $CH_4$, although their elastic cross
207: sections are nearly identical. However, the addition of even
208: small quantities ($\sim$0.1$\%$) of a molecular gas increases the
209: drift velocity in argon threefold and also alters the shape dependence
210: of $v_d$ on $E/P$~\cite{N2,book1}.
211: % In addition, in pure $Ar$ the drifting electrons obtain a rather
212: %low velocities in moderate electric fields, however, even small
213: %quantities (0.001??-10 $\%$) of molecular additives
214: %($H_2$,$CO_2$,$N_2$) increases the
215: %drift velocity in argon threefold and also alters the shape dependence
216: %of $V_d$ on E/p~\cite{book1,N2}.
217: In general, the drift velocity $v_d$ varies inversely with the
218: product of the total scattering cross-section $\sigma_{sc}$
219: and the square root of the mean electron energy
220: $\overline{\epsilon} $~\cite{fast1,fast2}.
221: Traditionally, the fast gas mixtures were achieved by
222: adding to $Ar$ a polyatomic gas~(usually a hydrocarbon or $CO_2$)
223: which effectively shifts the low energy part of the
224: electron distribution function into the region of the
225: Ramsauer-Townsend~(R-T) minimum, located at $\sim$ 0.5~eV,
226: of the momentum transfer and total electron scattering
227: cross-section of $Ar$.
228: The cooling of the electron swarm occurs as the energetic
229: electrons quickly transfer their energy to rotational and vibrational
230: modes of the polyatomic gas, whose scattering cross-section has a
231: large inelastic component to the right of the R-T minimum.
232: Furthermore, the cooling effect of a given gas in a high electric field
233: gas amplification region need not be the same as it's cooling effect
234: in the lower electric field drift region. As was shown
235: in~\cite{armit}, the very similar effects observed
236: in the $Ar/CH_4$ and $Ar/CO_2$ mixtures
237: in the avalanche region are contrasted
238: with different properties of these gases in the lower electric fields:
239: $CO_2$ is a much cooler gas than $CH_4$ in the drift region,
240: as is evidenced by the measured diffusion coefficients~\cite{cern}.
241: These results open the
242: possibility of choosing a gas mixture to separately optimize
243: the desired drift and gain behavior in a particular application.
244:
245: Almost twenty years ago, $CF_4$ has been proposed for
246: high rate environments as a most effective additive
247: to raise the drift velocity in noble gases.
248: This gas obtains its large drift velocity because of the
249: sizeable Ramsauer-Townsend dip in the elastic cross-section which coincides
250: with a very large vibrational inelastic cross-section~\cite{biagi}.
251: For the $Ar/CF_4$(90:10) mixture the
252: electron drift velocity was found to exceed 10~cm/$\mu s$,
253: which is twice as fast as for the conventional mixture
254: $Ar/CH_4$(90:10)~\cite{fast1}.
255: Further increase of the $CF_4$ fraction
256: in $Ar/CF_4$ mixtures tends to push
257: the maximum drift velocity to the higher field region,
258: but when the percentage of $CF_4$ becomes larger than 20~$\%$,
259: the $v_d$ is the same whatever the mixture,
260: indicating that it's mainly controlled by the $CF_4$
261: cross section~\cite{cf42,mix1,transport}.
262: The lower vibrational modes, as well as
263: the lower-lying negative ion states of $CF_4$ as compared to
264: $CH_4$, may account for the superior drift properties
265: of the $Ar/CF_4$ mixtures compared to
266: $Ar/CH_4$~\cite{christ,book2}.
267:
268: However, all binary $Ar/CF_4$ mixtures have rather poor energy
269: resolution, compared to $Ar/CH_4$, due to the production
270: of negative ions~\cite{fast1,attach}.
271: The dissociative attachment processes in $CF_4$ are the only mechanisms
272: leading to negative ion ($F^{-}$, $CF_3^{-}$) formation, via two
273: broad and overlapping resonances located between 4.5 and
274: 10~eV~\cite{cf42,cf41}, and can cause serious inefficiencies in the
275: collection of electrons and degrade the position resolution.
276: The main evidence for the electron attachment is the direct measurement
277: of the effective ionization coefficient $\overline{\alpha} = \alpha - \eta$;
278: where $\alpha$ and $\eta$ are, respectively, the electron impact ionization
279: and electron attachment coefficients. The negative values
280: of $\overline{\alpha}$ were observed in the drift region
281: in pure $CF_4$, $Ar/CF_4$(80:20) and
282: $Ar/CF_4/H_2 O$(80:18:2) mixtures. Very interestingly,
283: the electron thermalizing
284: properties effected by substituting 10~$\%$ of $CF_4$ in the
285: $Ar/CF_4$(80:20)
286: by 10~$\%$ of $CO_2$ virtually eliminates the electron attachment
287: in $Ar/CF_4/CO_2$(80:10:10) mixture~\cite{christ}.
288:
289: Moreover, due to the small $CF_4$ quenching cross-sections
290: of metastable $Ar$-states~\cite{quench1,quench2},
291: the $Ar/CF_4$ mixtures are not sufficiently
292: self-quenching and show an intolerable level of afterpulsing
293: even at moderate gas amplifications~(see also section 2.1).
294: This is not the case for the $Ar$/hydrocarbon mixtures, where
295: no significant afterpulsing was observed so far at moderate gas gains.
296: At the same time, some of the $Ar/CO_2$ mixtures are known to suffer from a low
297: sparkproofness~\cite{becker},
298: since the quenching ability of $CO_2$ is smaller than that of hydrocarbons.
299:
300: %\setlength{\unitlength}{1mm}
301: \begin{figure}[ph]
302: \setlength{\unitlength}{1mm}
303: \begin{picture}(160,200)
304: \put(-10.0,80.0){\special{psfile=fig1.eps vscale=58 hscale=56 } }
305: \put(75.0,80.0){\special{psfile=fig2.eps vscale=58 hscale=56 } }
306: \put(-10.0,-30.0){\special{psfile=fig3.eps vscale=58 hscale=56 } }
307: \put(75.0,-30.0){\special{psfile=fig4.eps vscale=58 hscale=56 } }
308: \put(20,120){ Figure 1: Electron drift velocity }
309: \put(30,114){ as a function of $E/P$ }
310: \put(103,120){Figure 2: Avalanche size curves as a }
311: \put(104,114){ function of HV for 5.9~keV $X$-rays }
312: \put(20,10){Figure 3: Tube chamber efficiency }
313: \put(35,4){ as a function of HV }
314: \put(103,10){Figure 4: Singles counting rates for a}
315: \put(103,4){ tube chambercell as a function of HV}
316: \end{picture}
317: %\caption[kk]{\em }
318: % \label{fig:point2}
319: \end{figure}
320:
321: The advantage of the enhanced drift velocity of $CF_4$
322: could be realized either in binary $CF_4$/quencher
323: or in ternary $Ar/CF_4$/quencher mixtures.
324: The choice of $CH_4$ among the hydrocarbons is
325: dictated by the requirements that the drift velocity in the
326: lighter hydrocarbons is larger than that in the heavier
327: ones~\cite{mix1}, especially in the low-field region.
328: Fig. 1 shows the drift velocity for the $Ar/CF_4/CH_4$(74:20:6),
329: $CF_4/CH_4$(90:10), $Ar/CF_4/CO_2$(65:30:5), $Ar/CF_4/CO_2$(80:10:10)
330: and $CF_4/CO_2$(90:10) mixtures, as a function of the electric
331: field strength at atmospheric pressure. These results are taken from
332: Refs.~\cite{christ,grimm,beck,mix2}. As can be seen from the curves,
333: the $CF_4/CH_4$ mixtures are significantly faster than
334: $CF_4/CO_2$ for any given value of $E/P$.
335: The use of $\afh$ could be more preferable for
336: high-rate proportional chamber applications than $CF_4/CH_4$ mixtures,
337: since the former shows fast rises in the drift velocity for
338: the relatively low fields, with respect to the latter,
339: and the mobilities of $CH_4^+$ ions in $Ar$
340: are much higher than those in $CF_4$,
341: which is desirable in terms of space charge effects~\cite{mix1,mix2}.
342: An additional disadvantage of the $CF_4/CH_4$ mixture is the necessity
343: to operate at high electric fields $E/P$ for a sufficient gas gain,
344: resulting in exceedingly high voltages in the chamber.
345: This could introduce a problem of electrostatic
346: instability of anode wires in large chambers.
347: Furthermore, considerations of cost and safety
348: led us to consider $Ar/CF_4/CH_4$ mixtures as a
349: reasonable compromise between many experimental requirements.
350: An optimization of the exact proportions of $Ar$, $CF_4$, and $CH_4$ in
351: the mixture was performed using the Magboltz and Garfield simulation programs.
352: As a result of simulation, $Ar/CF_4/CH_4$ (74:20:6) and another mixture
353: with a reduced $CH_4$ content $Ar/CF_4/CH_4$ (67:30:3) were chosen
354: for muon detector operation.
355: Unfortunately, mixtures with hydrocarbons have a tendency to
356: cause polymerization effects, while
357: $CO_2$ quencher has been proven to give a much longer lifetimes.
358: However, addition of $CO_2$ appreciably changes the drift properties
359: of the $Ar/CF_4/CO_2$ mixture, compared
360: to the case of $Ar/CF_4/CH_4$;
361: reduces the maximum drift velocity, and shifts it to the higher
362: field region.
363: In practice, we chose $Ar/CF_4/CO_2$(65:30:5) mixture,
364: as a fall back gas, if the aging criterion becomes dominant.
365:
366: Finally, in the $Ar/CF_4/CH_4$ (74:20:6),
367: $Ar/CF_4/CH_4$ (67:30:3) and $Ar/CF_4/CO_2$ (65:30:5) mixtures,
368: electron attachment processes may complicate gas performance.
369: However, the primary ionization in the chamber cell
370: is large enough and more than compensates for any losses due to
371: electron attachment, especially since only hit information is processed
372: in the muon detector.
373:
374: %\setlength{\unitlength}{1mm}
375: %\begin{figure}[ph]
376: % \begin{picture}(160,180)
377: % \put(-20.0,50.0){\special{psfile=fig1.eps vscale=58 hscale=56 } }
378: % \put(65.0,50.0){\special{psfile=fig2.eps vscale=58 hscale=56 } }
379: % \put(-20.0,-60.0){\special{psfile=fig3.eps vscale=58 hscale=56 } }
380: % \put(65.0,-60.0){\special{psfile=fig4.eps vscale=58 hscale=56 } }
381: % \put(5,90){ Figure 1: Electron drift velocity }
382: % \put(15,84){ as a function of $E/P$ }
383: % \put(88,90){Figure 2: Avalanche size curves as a }
384: % \put(89,84){ function of HV for 5.9~keV $X$-rays }
385: % \put(5,-20){Figure 3: Tube chamber efficiency }
386: % \put(20,-26){ as a function of HV }
387: % \put(88,-20){Figure 4: Singles counting rates for a}
388: % \put(88,-26){ tube chambercell as a function of HV}
389: % \end{picture}
390: %\caption[kk]{\em }
391: % \label{fig:point2}
392: %\end{figure}
393:
394:
395: \subsection{ Tube Chamber Characteristics. }
396:
397: In this paper, we address the problem of gas selection
398: and present the measured data only for tube
399: chambers.
400: The tube chamber is a closed-cell proportional wire chamber
401: made from an aluminum profile~(wall thickness 2~mm)
402: with a drift cell 14~$\times$~12~mm$^2$ in cross section.
403: Fig. 5 shows the schematic drawing of the tube chamber.
404: A gold-plated tungsten wire of 45~$\mu$m diameter and a length
405: of nearly 3~m is stretched inside each cell and fixed
406: mechanically with pins at the end of the chamber.
407: In order to prevent efficiency losses due to dead spaces between cells,
408: the tube chamber consists of two layers, each having 16 drift cells,
409: shifted with respect to each other by half a cell size.
410:
411: \begin{figure}[bth]
412: \setlength{\unitlength}{1mm}
413: \begin{picture}(100,50)
414: \put(40.0,8.0){\special{psfile=tubeb1.ps
415: voffset=0 hoffset=0 hscale=50 vscale=50 angle=0}}
416: \put(30,6){ Figure 5: Schematic drawing of the tube chamber. Dimensions are }
417: \put(40,0){ indicated in units of mm. }
418: \end{picture}
419: \end{figure}
420:
421: Firstly, we have collected the $Fe^{55}$ spectra for each mixture
422: under study: $\afh$ (74:20:6), $\afh$ (67:30:3) and $\afo$ (65:30:5)
423: with a goal of inferring the response to minimum ionizing particles.
424: % The $Fe^{55}$ spectra were collected for each mixture
425: %under study: $\afh$ (74:20:6), $\afh$ (67:30:3) and $\afo$ (65:30:5).
426: Measured pulse heights were converted to avalanche sizes,
427: which correspond to the total number of electrons in the
428: avalanche. The gas gain value
429: can be obtained by dividing the observed pulse size by $\sim$ 200,
430: the average number of primary electrons,
431: if the mixture has no electron attachment.
432: Fig. 2 shows the total avalanche size increasing in an exponential
433: manner with the high voltage, within the limits of the proportional region.
434: %All avalanche curves show good exponential behaviour
435: %within the limits of the proportional region, indicating a proper
436: %chamber operation.
437: It has been shown previously~\cite{gain1} that the onset
438: of secondary gas effects such as space charge saturation
439: may be detected as a break in the expected scaling
440: of the gas gain with respect both to anode surface field and
441: to gradient of the electric field near the wire.
442: It should be noted that for these data taken with an $Fe^{55}$
443: source with its fixed initial charge ($\sim$200 electrons),
444: a particular value of gas gain is equivalent to a definite value of the
445: total charge in the avalanche. Space charge effects depend on the
446: total avalanche size and distribution of the positive ion cloud. Hence,
447: these numerical results cannot be automatically applied to other
448: ionization sources with different magnitudes or distributions of the
449: initial charge.
450:
451: Secondly, the tube chamber characteristics have been
452: studied on the 3~GeV electron test beam at DESY.
453: The beam intensity was $\sim$~1~$kHz/cm^{2}$.
454: The trigger was initiated by a coincidence of
455: four beam-defining scintillator counters,
456: between which the chamber was positioned.
457: %Using a coincidence between the counters as a trigger,
458: Then, the number of events with at least one hit in the double layer
459: chamber, within the 96~ns, versus the number of triggered events
460: yields an efficiency.
461: Fig. 3 shows the measured efficiency
462: for the mixtures being studied, as a function of high voltage.
463: This figure demonstrates, that the actual efficiency is approximately
464: 100~$\%$ for the double layer chamber.
465: However, for a single layer the usage of $\afo$(65:30:5) mixture
466: results in about 7~$\%$ of signals registered outside the 96~ns
467: (for perpendicular tracks), while in $\afh$ mixture nearly all
468: signals are collected within the 96~ns.
469: Fig. 4 presents singles (untriggered) counting rates for a
470: tube chamber cell as a function of high voltage.
471: From these curves, wide high voltage plateaus for a stable
472: and efficient operation
473: with the $\afh$(74:20:6), $\afh$(67:30:3) and $\afo$(65:30:5) gases
474: are observed, where the counting rate is roughly uniform.
475: Real afterpulses and multiple hits of ASD-8 per signal both
476: contribute to the rise in singles rate curves, above the
477: nominal beam intensity, with increasing high voltage.
478: In comparison, $Ar/CF_4$(70:30) mixture
479: will not guarantee stable and efficient operation over
480: sufficient high-voltage range in the tube chambers.
481: The difference in singles rate curves, and correspondingly
482: in detection efficiency,
483: between $Ar/CF_4$(70:30) and $\afh$(67:30:3)
484: may be attributed to the enhanced gas electron production efficiency
485: and smaller electron attachment for the latter mixture.
486: In addition, onset of secondary avalanches in $Ar/CF_4$
487: limit the maximum operating voltage to 2.5~kV~(see Fig. 4), thus
488: causing a drastic decrease in the counting rate plateau width.
489:
490: The results presented here justify
491: the choice of $\afh$ (74:20:6), $\afh$ (67:30:3) and $\afo$ (65:30:5)
492: gases for muon detection with high efficiency.
493: %The radiation hardness of these mixtures will be discussed in sections 4-5.
494:
495:
496: \section{ General characteristics of aging processes. }
497:
498: Aging effects in proportional wire chambers,
499: a permanent degradation of operating
500: characteristics under sustained irradiation, has been and remains
501: the main limitation to their use in high-rate experiments~\cite{charpak}.
502: Many processes are expected to occur simultaneously in the
503: gaseous discharges surrounding the wire
504: and it is nearly impossible to obtain
505: a quantitative chemical description in each particular case.
506: There is much experimental information, excellently
507: summarized in~\cite{workshop,kadyk,vavra,cern1}, that suggests the
508: wire chambers lifetime could be affected, and in some cases
509: dramatically, by the nature and purity
510: of the gas mixture, materials used in contact with the gas,
511: by different additives, and trace contaminants.
512:
513: While the specific reactions responsible for wire chamber aging
514: are extremely complex,
515: a qualitative description of the aging phenomena
516: in different gases could be obtained
517: from similarities between chemical processes in wire chamber
518: avalanches and those
519: that occur in the better-understood low-pressure
520: rf-plasmas~\cite{kadyk,vavra,gcms,chemmod,hess}.
521: During wire avalanches many molecules break up
522: by collisions with electrons, de-excitation of atoms,
523: and UV-photon absorption processes.
524: Whereas most ionization processes require electron energies
525: greater than 10~eV,
526: the breaking of the chemical bonds in molecules and formation of free
527: radicals requires only 3-4~eV, and could lead to a large
528: abundance of free radicals over the ions in the wire avalanches.
529: Similar to plasma polymerization~\cite{yasuda},
530: a free-radical polymerization
531: seems to be the most appropriate mechanism of the wire chamber aging.
532: Since free radicals are chemically very active they will either
533: % Once free radicals formed, they
534: %are chemically very active and will either
535: recombine back to original molecules or other volatile species,
536: or form new cross-linked molecular structures,
537: which could react further to produce chain-like polymers
538: of increasing molecular weight, thus lowering
539: the volatility of the resulting product.
540: When the growing of polymerized chain becomes large enough
541: for condensation to occur, it will diffuse to the
542: electrode surface.
543: The polymer deposition mechanism can be
544: conceived as a phenomenon that
545: occurs whenever the gaseous species fails to bounce back on
546: collision with a electrode surface, including a surface of particles
547: already formed in the gas discharges.
548: Initially the polymer could be held to the surface very weakly,
549: %and could be easily blown away by a large gas flow,
550: unless
551: some additional chemical reaction takes place between the polymer
552: atoms and atoms of the wire material.
553: Furthermore, many free radicals are expected to have
554: permanent or induced dipole moments; therefore,
555: electrostatic attraction to a wire could
556: play a significant role in the polymer deposition process.
557: %especially since the rates of some reactions
558: %in the vicinity of the wire may increase
559: %quadratically with the high free radical concentration.
560: Thus, aging effects in gaseous detectors would lead to
561: deposition of thin, very high quality polymers on the anode wires,
562: and would result in a loss of the gas gain and degradation
563: of ionization measurements.
564: Deposits on cathodes can induce discharges by secondary
565: electron emission (or Malter effect~\cite{malter}), and would lead to
566: chamber breakdown.
567:
568:
569: Traditionally, the aging rate was parameterized as a normalized gas gain
570: loss~\cite{kadyk}:
571:
572: \[ R = - \frac{1}{G} \frac{dG}{dQ} ( \%~per~C/cm ) \]
573:
574: where $G$ is an initial gas gain,
575: $dG$ is the loss of gas gain after collected charge $Q$ per
576: unit length.
577: The parameterization used above implicitly assumes that the gain drop
578: depends linearly on the charge collected per unit length of the wire, and
579: that the aging rate is only a function of the total collected charge,
580: independent of gas gain and radiation intensity. In reality, this
581: assumption is not fulfilled.
582: Several examples in the literature~\cite{juri,kott,opensh1,algeri,cern1}
583: clearly indicate that the degree of aging for a given
584: radiation dose could also depend upon the mode of operation,
585: being larger for smaller current densities, other conditions
586: being held constant. These observations raise a question on the
587: relevance of aging results, obtained in accelerated aging tests
588: with extremely high current densities, extrapolated to
589: normal conditions.
590: Moreover, aging studies of ATLAS muon drift tubes,
591: %irradiated over a large area,
592: have shown a strong dependence of the aging
593: rate on the mode of operation (irradiation rate, high voltage)
594: and size of the irradiated area~\cite{dissert}.
595: Furthermore, it has been found that
596: the aging rate in the HERA-B honeycomb tracker chambers varies
597: substantially, when changing from $\gamma$ irradiation
598: %by orders of magnitude, when changing from $\gamma$ irradiation
599: to heavy ionizing particles~(see section 3.1).
600: This paper presents evidence that the
601: aging rate for irradiation with 5.9~keV $X$-rays and
602: 100~MeV $\alpha$'s may differ by more than two orders of
603: magnitude~(see sections 4 and 5).
604: Furthermore, it was recently reported in~\cite{lyon} and
605: it will be shown in a subsequent paper~\cite{hadr}, that
606: the rate of polymer deposition could also be affected by the
607: mode of operation, size of the irradiated area and
608: water addition.
609:
610:
611: % This paper also presents an evidence that the
612: %rate of polymer deposition could be affected by the
613: %mode of operation and by the size of irradiation area~(see sections 4,5,6).
614:
615: These results exclude the possibility to extrapolate aging
616: rates obtained in the laboratory setups by irradiating
617: a small region of the wire to the large areas of
618: irradiation in hadronic environment. Therefore, for each
619: particular case, the final decision for long-term
620: stability of operation should be taken only after obtaining similar
621: performance in conditions as close as possible to real ones.
622:
623: \subsection{ Results from wire chambers operation. }
624:
625: Over the last few decades, an impressive variety of
626: experimental data has been accumulated and it is not feasible
627: to go through all published results. In addition, new
628: results make doubtful the quantitative comparison of
629: aging properties, realized at very different conditions.
630: Therefore, we will present below only a brief summary of the most recent
631: data, focusing on the binary and ternary mixtures, containing
632: $Ar$, $CH_4$, $CO_2$ and $CF_4$.
633:
634: There are a lot of reports
635: that clearly indicate premature aging in $Ar/CH_4$ filled
636: wire chambers exposed to intense
637: radiation~\cite{juri,tsarnas,smith,kollef,kwong}.
638: The polymerization of $CH_4$ is attributed to the
639: hydrogen deficiency of radicals and their ability to make bonds
640: with hydrocarbon molecules~\cite{kadyk,yasuda}, leading
641: to the buildup of deposits
642: on the anode wires, which usually contain carbon and lighter
643: elements.
644:
645: Attempts were made to replace the organic quenchers with more
646: stable ones, such as $CO_2$.
647: However, the gradual decomposition of $CO_2$ in $Ar/CO_2$ mixtures
648: also takes place and stable operation
649: was found to be possible up to charges of
650: 0.5-0.7~$\frac{C}{cm~wire}$~\cite{vavra,atlas}.
651: Furthermore, carbon dioxide is also known for its
652: carbon buildup, which occurs specifically at the
653: cathode~\cite{co2}, however, this carbon layer
654: did not affect the performance of the drift
655: tubes~\cite{atlas}.
656: Another effect, which is enhanced in $Ar/CO_2$ mixtures
657: compared to gases containing hydrocarbon quenchers,
658: is the spurious counting rate~(noise), that presumably comes
659: from the spikes on the wires. This noise
660: can be cured by the
661: addition of water vapor to the drift gas~\cite{atlas}.
662:
663:
664: The aging studies in the ternary mixtures $Ar/CH_4/CO_2$
665: indicate the dependence of the aging rate on the
666: particular set of operating conditions,
667: in some cases being smaller for larger $CH_4$ content
668: in the mixture~\cite{kott,atlasnote,sadr}.
669: The stable operation far beyond 0.6~$\frac{C}{cm~wire}$
670: was observed for $Ar/CH_4/N_2/CO_2$ (94:3:2:1)
671: + 1200~$ppm$ of $H_2 O$ mixture, however,
672: some conditions where found were only a tenth of
673: nominal lifetime was achieved~\cite{kollef}. Moreover,
674: for the $Ar/CH_4/N_2/CO_2$ mixture, measurements have shown
675: that their sensitivity to aging decreases with
676: decreasing $CH_4$ and increasing $CO_2$ content.
677:
678: The use of gases having $CF_4$ as a component was found to be
679: attractive in the plasma processes, since the $CF_4$
680: is an ideal source for a variety of reactive neutral and ionic
681: fragment atoms and molecules,
682: and especially neutral fluor, which is a
683: desirable active species in etching processes~\cite{mogab}.
684: The $CF_4$ molecule is
685: %a attractive gas component because it is
686: relatively inert in its electronic ground state, but
687: all excited electronic states of $CF_4$ and $CF_4^{+}$ ion
688: lead to dissociation.
689: Below the onset of electronic excitations, which is rather
690: high - 12.5~eV, collisions of electrons with $CF_4$ molecule
691: lead to elastic scattering, vibrational excitation and
692: dissociative attachment. Above this energy,
693: dissociation of the $CF_4$ into neutrals or charged
694: fragments becomes significant~\cite{cf42,cf41}.
695: Actually, in plasma environment $CF_4$-based gases are used for
696: both etching and deposition processes,
697: the distinction being made by the gas and its amount with which $CF_4$ is mixed.
698: The balance between these processes is called 'competitive
699: ablation and polymerization'.
700: In general, the addition of
701: oxygenated species shifts the chemistry of $CF_4$ plasmas toward
702: etching, while the addition of hydrogenated species shifts the
703: chemistry toward polymerization~\cite{chemmod,yasuda,kushner,winters}.
704: For example, the polymer formation by $CF_4$ plasmas
705: in the presence of $CH_4$ was observed~\cite{yasuda}.
706:
707: In the wire chamber operation, the usage of $CF_4$ is
708: also quite controversial.
709: Many studies have demonstrated excellent aging properties,
710: up to 10~$\frac{C}{cm~wire}$,
711: of $CF_4/i C_4 H_{10}$ (80:20) avalanches~\cite{kadyk1,opensh},
712: which also
713: has an ability to etch both silicon-based~\cite{kadyk,opensh} and
714: hydrocarbon~\cite{opensh} deposits from the previously aged
715: gold-plated wires.
716: However, another proportions of $CF_4$
717: and isobutane could totally change the chemical reactions on the surface
718: of the anode wire.
719: Heavy carbonaceous deposits were formed on the gold-plated
720: wires irradiated in the mixtures $CF_4/i C_4 H_{10}$ (95:5) and
721: $CF_4/i C_4 H_{10}$ (20:80). The absence
722: of fluorocarbon deposits on the anode wires
723: indicates that the deposits were formed only from $i C_4 H_{10}$,
724: without incorporation of $CF_x$ fragments.
725: Details of the chemical model and aging results in the
726: $CF_4/i C_4 H_{10}$ are presented elsewhere~\cite{chemmod}.
727: Another gas observed to form heavy carbonaceous anode deposits
728: was $CF_4/C_2 H_4$(95:5)~\cite{chemmod}. At the same time,
729: the 4 $\%$ addition of $CF_4$ has been shown to inhibit anode damage
730: in $Ar/C_2H_6$(50:50) mixture up to the doses of
731: 1.5~$\frac{C}{cm~wire}$~\cite{opensh1}. Aging studies have been
732: also performed with the $CF_4/CH_4$ (90:10) gas mixture
733: %for the D0 muon test chamber and
734: and no deterioration was found up to 1.9~C/cm of the wire~\cite{d0}.
735: Finally, it should be noted, that most of the aging studies in the
736: $CF_4$/hydrocarbon mixtures, were performed by irradiating a small region of the wire
737: under well controlled laboratory conditions.
738: At the same time, several painful experiences with aging
739: are known from the high energy experiments.
740: The D0 muon drift chambers,
741: filled with $Ar/CF_4/CH_4$(80:10:10) undergo a fast aging when
742: operated in a radiation environment.
743: Vapors from a glue used in the construction were deposited on the wires
744: in a sheath, with the deposition rate proportional to accumulated charge~\cite{d0note}.
745: Furthermore, operation in the high-rate hadronic HERA-B environment
746: showed that the aging rate could depend on the type of
747: ionization and size of the irradiated area~\cite{hohlmann,kolanoski}.
748: The severe anode and cathode aging effects
749: were observed in the honeycomb chambers tested in the
750: HERA-B conditions with $CF_4/CH_4$(80:20) and $Ar/CF_4/CH_4$(74:20:6) mixtures
751: after the radiation dose of several $mC$ per $cm$ of the wire.
752: This effect was surprising since the
753: chambers were proved to be immune a very large $X$-ray doses, up to
754: the 5~C/cm of the wire.
755:
756: The aging properties of the gas mixtures
757: $Ar(Xe)/CF_4/CO_2$, which by analogy with plasma experiments
758: should provide etching environments in the wire avalanches,
759: have been also widely investigated over the past years.
760: The radiation tests of the ATLAS straw tubes using
761: $Xe/CF_4/CO_2$ mixture showed no signs of aging
762: for a integrated charge of up to 8~$C/cm$~\cite{akesson,straw}.
763: However, the
764: detailed examination of anode wires and straw walls (cathode)
765: after irradiation had shown evidence for the etching
766: processes on both surfaces~\cite{romaniouk}.
767: Another interesting phenomena was found in straw tubes
768: irradiated under exceedingly high current densities in $Xe/CF_4/CO_2$ mixture.
769: %with a $Sr^{90}$ source in $Xe/CF_4/CO_2$ mixture
770: %under exceedingly high current densities.
771: After an accumulated charge of 9~$C/cm$ the
772: `anode swelling effect' was observed,
773: where destruction of gold coating of the gold-plated tungsten wires,
774: followed by the tungsten oxidation~\cite{kriv1,kriv2}.
775: Recently, it was also reported~\cite{hohlmann,kolanoski}, that
776: under a high radiation intensity in $\afo$ (65:30:5) mixture,
777: gold-plating of tungsten wires
778: can be etched away completely exposing the tungsten.
779: However, the addition of
780: water to the $\afo$ (65:30:5) was found to reduce the rate of
781: etching processes, and the honeycomb chambers were able to survive
782: radiation doses of up to 2~$\frac{C}{cm~wire}$.
783: The chemical etching processes in the $\afo$
784: are likely to be responsible for the
785: enhanced removal of the diamond coating observed in
786: MSGC-GEM chambers~\cite{beauty}.
787:
788: Amazingly, extremely rapid aging has been observed
789: for pure $CF_4$ and in $Ar/CF_4/O_2$(50:40:10) mixture,
790: which were expected to have strong etching abilities~\cite{chemmod,coyle}.
791: In the former case, the aging process was related to chemical processes
792: at the cathode, where trace fluorocarbon deposits were found.
793: This type of aging phenomena was found to be cathode-material-dependent,
794: and resulted in a loss
795: of gas gain rather than in a self-sustained discharge.
796: For the latter case, although $C$, $O$, and $F$ elements were observed
797: on the anode wire, it is likely that the rapid aging was as a result of
798: the same (cathode phenomenon) observed in pure $CF_4$.
799: The fluorination
800: of the anode wires, found after exposure in $Ar/CF_4/O_2$(50:40:10) avalanches,
801: can cause anode aging in addition to cathode effects~\cite{chemmod}.
802: A further phenomena due to the consistency of the cathode surfaces
803: was observed in ATLAS aluminum drift tubes operated in
804: $Ar/CF_4/N_2/CO_2$ (94.5:0.5:2:3). Here, no change in gas gain
805: for the tubes was found up to an accumulated charge of
806: 5~$\frac{C}{cm~wire}$.
807: However, the increased count rate at the beginning of the tests,
808: due to afterpulses in this gas at high gains
809: decreased with the time to the level, when no significant
810: afterpulsing was observed.
811: This reduction was suggested to be due to the increased layer
812: of fluor and oxygen found at the cathode~\cite{dissert}.
813: Similar effects were also found during the long-term irradiation of drift tubes
814: with stainless steel cathodes in pure $CF_4$~\cite{denisov}.
815:
816: These aging results clearly demonstrate that
817: the presence of large amounts of $CF_4$ in the mixture does not
818: necessarily ensure good aging properties.
819: Moreover, perfluorocarbons represent the most extreme case of ablation
820: competing with polymer formation.
821: Therefore, all attempts
822: to improve the aging performance of the mixtures by adding $CF_4$
823: must be tested in the actual environment.
824:
825: An abundance of literature exists describing the effect of certain additives
826: with oxygen-containing groups, like water, alcohol, methylal, oxygen.
827: These components, added to the mixture in small concentrations,
828: usually (but not always) extend the chamber lifetime,
829: especially against the polymerization of hydrocarbons.
830: Of special interest is the addition of water vapors,
831: that has been found to suppress effectively polymerization in
832: wire chambers~\cite{kollef,charm}, to prevent Malter breakdowns~\cite{straw1},
833: or even to restore the original operation in aged
834: counters~\cite{algeri,argus}; a few hundred to a few thousand $ppm$ of water
835: are generally used. The most natural mechanism by which water impedes Malter
836: breakdowns and significantly improves the analog response of the
837: aged counters comes from the fact that water tends to increase the
838: conductivity of the damaged electrodes~\cite{kadyk,algeri}.
839: In addition, water could
840: effectively suppress the secondary photon-mediated phenomena, if
841: the UV photons from carbon excitations are responsible for the
842: photoionization at the cathode~\cite{vavra2}. At the same time, the
843: exact mechanism by which water stops or reduces the aging rate
844: in wire chambers is not clearly understood. One possible explanation
845: could be gained from the similarities with plasma chemistry,
846: where water acts like a blocking agent of the chain growth
847: mechanism, reacting with polymer precursors, thereby decreasing the
848: concentration of free radicals available for polymerization~\cite{yasuda}.
849: Another explanation is that water, due to its large dipole moment,
850: could effectively slow-down electrons in the avalanches
851: making the mixture `cooler'. In this case, aging effects resulting from free
852: radical polymerization would be reduced, since fewer
853: radicals would be formed in the wire avalanches.
854: Finally, it is well established, that
855: aging effects in the wire chambers, even when they are entirely due to
856: polymerization of gas mixture components can be accelerated by the
857: discharges~(glow discharges of sparks)
858: and photoelectric feedback~\cite{vavra2,atac}.
859: These effects are strongly dependent on the quality and type of the
860: electrodes: surfaces of anode wire or cathode could be rather
861: imperfect, thus, `triggering' polymerization in wire chambers.
862: Known remedies for aging in this case are also water and alcohols,
863: which may prolong the lifetime considerably.
864: Furthermore, aging can be
865: initiated by the trace contaminants such as $Si$, halogens~(other than $CF_4$),
866: sulfur, phthalats, benzine rings, which are either initially present in the
867: gas, or result from outgassing of solid materials in contact with gas.
868: The detailed summary of the influence of
869: commonly used materials on aging properties
870: may be found in ~\cite{kadyk,romaniouk}.
871: When constructing large systems,
872: one should before to certify the gas purity and chemical reactivity
873: of various materials in order to avoid the presence of 'bad' molecules
874: in contact with the active gas volume.
875: %Therefore, for the new high-intensity experiments, all precautions should be taken
876: %in order to avoid the presense of 'bad' malecules or materials in contact
877: %with the active gas volume.
878:
879:
880:
881: \section{ Aging results from laboratory tests.}
882:
883: We have carried out a laboratory study of the aging properties
884: of $\afh$ (74:20:6) mixture, when exposed to an intensive $Fe^{55}$ source,
885: and of $\afh$ (67:30:3) and $\afo$ (65:30:5) mixtures, both irradiated
886: with a $Ru^{106}$ source, up to
887: a total radiation dose of 2~$C/cm$ of the wire.
888: In each test, a single cell
889: of the proportional tube chamber was irradiated through
890: a hole in the cathode wall, closed with thin $Al$ foil,
891: in the center of the 50~cm long cell.
892: The irradiated area was limited by a collimator
893: to about 30~mm of the wire for the $Fe^{55}$ source
894: and to 10~mm for the $Ru^{106}$ source.
895: While the $Fe^{55}$ 5.9~keV $X$-rays produce
896: an ionization cluster in the chamber cell,
897: corresponding to $\sim$~200 primary electrons, the
898: $Ru^{106}$ source provides 3.54~MeV electrons
899: from the decay of $Rh^{106}$, which leaves an ionization track
900: with $\sim$~90 primary electrons per cm.
901: The degree of aging was determined quantitatively by
902: comparing $Fe^{55}$ spectra, measured at the irradiated and reference
903: positions of the wire, using the same electronics chain.
904: This method removed problems
905: arising from the $Fe^{55}$ peak position movement due to changes in
906: the pressure, the temperature, and gas mixture itself.
907: %since the measurements are performed at both positions under identical
908: %conditions.
909: The total collected charge was
910: determined by integrating continuously the recorded anode current.
911: The gas flow rate was 1~liter/hour for all tests.
912:
913: \setlength{\unitlength}{1mm}
914: \begin{figure}[bth]
915: \begin{picture}(160,110)
916: \put(-15.0,-20.0){\special{psfile=fig5.eps vscale=58 hscale=56 } }
917: \put(70.0,-20.0){\special{psfile=fig6.eps vscale=58 hscale=56 } }
918: \put(11,20){Figure 6: Ratio of $Fe^{55}$ peak positions }
919: \put(12,14){ at irradiated and reference spots as a}
920: \put(14,8){ function of the accumulated charge. }
921: \put(102,20){Figure 7: Measured dependence of a}
922: \put(106,14){self-sustained dark current as a }
923: \put(106,8){ function of gas flow, after the }
924: \put(104,2){ removal of the irradiation source. }
925: \end{picture}
926: %\caption[kk]{\em }
927: % \label{fig:point2}
928: \end{figure}
929:
930: A standardized set of conditions was established for the $Fe^{55}$
931: irradiation of the $\afh$ (74:20:6) mixture, corresponding to a current of
932: 0.7~$\mu A/cm$ at a HV=2.65~kV.
933: %and leading to a mean avalanche size of $Q \sim 3 \times 10^{8}$.
934: For irradiation with the $Ru^{106}$ source, the high voltages for
935: operation in $\afh$ (67:30:3)~($\afo$ (65:30:5)) mixtures
936: were set to 2690~V (2790~V), corresponding to current densities
937: of 1.2~$\mu A$ (0.9~$\mu A$).
938: % and leading to mean avalanche sizes
939: % $Q \sim 6 \times 10^{7}$ ($Q \sim 4 \times 10^{8}$) respectively.
940: The different current densities for the
941: irradiation of $\afh$ (67:30:3) and $\afo$ (65:30:5) mixtures
942: is attributed to the reduced source strength for the latter case,
943: due to the larger thickness of $Al$ foil used
944: as a cathode above the irradiated region of the wire.
945: The high voltages used during the aging studies already exceed
946: the proportional mode of gas amplification,
947: therefore, events with higher pulse heights than those in the
948: proportional mode also appear at these voltages.
949: % Moreover, the higher space-charge
950: %effects induced by the 5.9~keV $X$-rays,
951: %compared with electrons from $Ru^{106}$,
952: %could result in a larger fraction of the the registered events
953: %already in the self-quenching streamer~(SQS) mode
954: %for the irradiation with $Fe^{55}$ source.
955: % The difference in chamber behaviour ....
956:
957: % The higher space-charge effects created by the $Fe^{55}$ source
958: %compared with $Ru^{106}$ promotes the transition from the
959: %proportional to the self-quenching streamer~(SQS) mode, and could
960: %result in a larger number of the the registered events
961: %already in the SQS mode for the former case.
962:
963: Fig. 6 shows the ratio of $Fe^{55}$ peak positions, measured
964: at irradiated and reference spots as a function of the accumulated charge.
965: For the $\afh$ (74:20:6) mixture,
966: the relative mean amplitude $\frac{A_{irrad}}{A_{reference}}$
967: monotonously dropped to about 85~$\%$ of the initial value,
968: after the radiation dose of 2~$C/cm$ of the wire,
969: corresponding to $R \sim 8~$ $\%$ /~$C/cm$.
970: %Despite these degradings,
971: Such a rate of gas gain losses could be acceptable for the long-term
972: operation of the muon chambers in HERA-B.
973: However, after a collected charge $\sim$ 1~$C/cm$
974: significant self-sustained dark current
975: appeared in addition to those normally associated with radiation.
976: This dark current persisted even after the removal of
977: the radiation source, but it
978: was totally quenched, either by a large increase in the gas flow rate,
979: from 1~liter/hour to 10~liters/hour~(see Fig. 7),
980: or by turning off the high voltage.
981: This phenomena is associated with the polymer coating
982: and subsequent charge buildup on the cathode surface,
983: by a mechanism similar to the well known Malter discharge~\cite{malter}.
984:
985: Irradiation with the $Ru^{106}$ source of
986: $\afh$ (67:30:3) and $\afo$ (65:30:5) mixtures
987: led to $R$ values consistent with zero~(see Fig. 6).
988: Such promising aging behavior make these gases suitable candidates
989: for use in the tube chambers. Unfortunately, as will be reported
990: in section 5, the aging results, obtained in the high-rate
991: hadronic environment when irradiating a large area chamber differ
992: significantly from those described above.
993:
994: \section{ Aging studies in a 100~MeV $\alpha$-beam }
995:
996: \subsection{ Aging in $\afh$(74:20:6) gas mixture.}
997:
998: After the tests with radioactive sources,
999: aging studies with the $\afh$ (74:20:6) mixture were carried out
1000: by irradiating a single layer tube chamber
1001: in a 100~MeV $\alpha$-beam in Karlsruhe~(see Fig. 8).
1002: Due to the small range of the 100~MeV $\alpha$'s
1003: in aluminum, the thickness of the $Al$-wall
1004: was reduced to $\sim$ 200~$\mu m$.
1005: The $\alpha$-beam intensity was
1006: almost uniform over the beam area 8~$\times$~8~$cm^2$.
1007: This allowed a constant
1008: irradiation of four
1009: wires fully, and, in addition, two
1010: wires were exposed over half of their cell width.
1011: All wires were equipped for analog readout.
1012: Furthermore, for one of wires, which we will call a `reference wire',
1013: two holes were made in the chamber wall - within the region
1014: of irradiation and outside of it. Both holes
1015: were closed with kapton foil.
1016: For the `reference wire', it was possible
1017: to measure the degree of aging by comparing the $Fe^{55}$
1018: spectra at the two positions of the same wire.
1019:
1020: A premixed gas mixture of $\afh$(74:20:6)
1021: was transported by stainless-steel tubes connected directly
1022: to the tube chamber inlet and outlet. The gas flow was in serial
1023: inside a chamber from one cell to another,
1024: with the flow rate about 6~liters/hour.
1025: The operating voltage was set to 2.35 kV, corresponding to a
1026: gas gain $\sim 4 \times 10^{4}$, measured with $Fe^{55}$ $X$-rays.
1027: The radiation intensity varied during the aging studies
1028: by a factor of 3, thus excluding any possibility to
1029: investigate aging behavior as a function of rate.
1030: Therefore, the current densities were in the range
1031: $\sim$~250~nA/cm up to 750~nA/cm.
1032: By monitoring the chamber current, the total collected charge
1033: was determined.
1034:
1035: Since the average energy losses of $\alpha$-particles
1036: in the chamber cell are much larger than those of $X$-rays,
1037: the same avalanche size as that for $X$-rays is obtained
1038: at a lower voltage.
1039: In practice, at an applied voltage of 2.35~kV,
1040: the total charge released from $\alpha$-particles
1041: was measured to be a factor of 10-15
1042: larger than that corresponding to a 5.9~keV $X$-ray
1043: localized energy deposition in proportional mode.
1044: Moreover, the signals from $\alpha$'s at this voltage
1045: were also accompanied by self-quenching streamer discharges,
1046: observed in several percent of the events at this voltage.
1047: This may be explained by the fact that since the transformation
1048: from proportional to streamer mode depends upon the primary
1049: ionization density~\cite{gang}, heavily ionizing particles should enter
1050: the self-quenching streamer mode at lower voltages than $Fe^{55}$ $X$-rays
1051: and minimum ionizing particles.
1052:
1053: \setlength{\unitlength}{1mm}
1054: \begin{figure}[bth]
1055: \begin{picture}(160,110)
1056: \put(-40.0,-37.0){\special{psfile=fig7.eps vscale=80 hscale=80 } }
1057: \put(75.0,-20.0){\special{psfile=fig8.eps vscale=58 hscale=56 } }
1058: \put(11,20){Figure 8: Sketch of the tube chamber }
1059: \put(12,14){ used in the $\alpha$-beam in Karlsruhe. }
1060: % \put(0,-2){ function of the accumulated charge. }
1061: \put(102,20){Figure 9: Singles rate curves for the }
1062: \put(102,14){ `reference wire' in the irradiated region }
1063: \put(102,8){ (stars), after exposure to 60~$\frac{mC}{cm~wire}$,}
1064: \put(108,2){ and outside of it (circles). }
1065: \end{picture}
1066: %\caption[kk]{\em }
1067: % \label{fig:point2}
1068: \end{figure}
1069:
1070:
1071: After the first 24 hours of irradiation, which resulted in a
1072: collected charge of $\sim$~50~$\frac{mC}{cm~wire}$,
1073: the status of the `reference wire' was checked
1074: by recording the $Fe^{55}$ pulse-height spectra.
1075: Severe anode aging was observed for this wire
1076: in the irradiated area, corresponding to a normalized gas gain
1077: loss value $R \sim 750~\%~per~C/cm $, while the $Fe^{55}$
1078: spectra in the non-irradiated region remained unchanged.
1079: The downward shift of the peak value was accompanied by a
1080: distortion and broadening of the $Fe^{55}$ pulse-height spectrum.
1081: After the next 6 hours of exposure, when an additional
1082: 10~$\frac{mC}{cm~wire}$ were collected,
1083: a steady decrease of the
1084: gas gain for the `reference wire' has been found, and the $R$ value
1085: became even slightly higher $\sim 850~\%~per~C/cm $.
1086: Furthermore, during these hours,
1087: sizeable increase in the single counting rate,
1088: above the actual $\alpha$-beam intensity,
1089: was observed from several of the irradiated wires.
1090: Since that time, the irradiation of the `reference wire' was
1091: halted, but, the aging studies with all other wires were continued
1092: until the collected charge
1093: had reached a value of 280~$\frac{mC}{cm~wire}$.
1094: Two wires, irradiated over half of their cell width, accumulated
1095: half of this charge - 140~$\frac{mC}{cm~wire}$.
1096: The aging behavior of the wires during irradiation was quite similar:
1097: large increase in the single counting rate, as a result of
1098: spark discharges,
1099: was observed from all wires at an applied voltage of
1100: 2.35~kV, together with the monotonic
1101: drop in the chamber current.
1102:
1103: %\setlength{\unitlength}{1mm}
1104: %\begin{figure}[bth]
1105: % \begin{picture}(160,110)
1106: % \put(-50.0,-37.0){\special{psfile=fig7.eps vscale=80 hscale=80 } }
1107: % \put(65.0,-20.0){\special{psfile=fig8.eps vscale=58 hscale=56 } }
1108: % \put(-3,20){Figure 8: Experimental setup at the }
1109: % \put(-2,14){ $\alpha$-beam in Karlsruhe. }
1110: % \put(0,-2){ function of the accumulated charge. }
1111: % \put(88,20){Figure 9: Singles rate curves for the }
1112: % \put(87,14){ `reference wire' in the irradiated region }
1113: % \put(88,8){ (stars) and outside of it (circles) }
1114: % \put(90,2){ after exposure to 60~$\frac{mC}{cm~wire}$. }
1115: % \end{picture}
1116: %\caption[kk]{\em }
1117: % \label{fig:point2}
1118: %\end{figure}
1119:
1120: \setlength{\unitlength}{1mm}
1121: \begin{figure}[ph]
1122: \begin{picture}(160,200)
1123: \put(40.0,160.0){\special{psfile=fig10.ps vscale=45 hscale=48 } }
1124: \put(40.0,85.0){\special{psfile=fig11.ps vscale=45 hscale=48 } }
1125: \put(10.0,15.0){\special{psfile=fig12.ps vscale=36 hscale=36 } }
1126: \put(93.0,3.0){\special{psfile=fig13.ps vscale=30 hscale=35 } }
1127: \put(15,153){Figure 10: SEM of the 'reference wire' after the accumulated charge of 60~$\frac{mC}{cm~wire}$.}
1128: \put(15,147){ $C$ and $F$
1129: elements were identified together with Au signal from the wire material.}
1130: % \put(0,138){ together with Au signal from the wire material.}
1131: \put(15,83){Figure 11: SEM of the cathode surface composition in the irradiated region }
1132: \put(35,77){ of the wire after exposure to 280~$\frac{mC}{cm~wire}$. }
1133: \put(13,8){Figure 12: Typical deposits on the }
1134: \put(9,2){ anode wire after exposure to 280~$\frac{mC}{cm~wire}$.}
1135: % \put(0,-12){ 240~$\frac{mC}{cm~wire}$. }
1136: \put(98,8){Figure 13: Wire irradiated over half }
1137: \put(98,2){ of its cell width. Deposits built}
1138: \put(98,-4){up on one side of the wire towards }
1139: \put(98,-10){all of the primary electrons drifted. }
1140: \end{picture}
1141: %\caption[kk]{\em }
1142: % \label{fig:point2}
1143: \end{figure}
1144:
1145: After the aging studies in Karlsruhe, the chamber characteristics
1146: have been studied on the 3~GeV electron beam with intensity
1147: $\sim$~1~$kHz/cm^{2}$.
1148: Fig. 9 shows the singles rate curves for the `reference wire'
1149: in the irradiated region, after exposure to
1150: 60~$\frac{mC}{cm~wire}$, and outside of it.
1151: From these curves it is seen that, as result of irradiation,
1152: there is a shift upwards of the
1153: lower end of the efficiency plateau~(showing a decrease of gain
1154: at a given voltage) with a
1155: consequent reduction in effective plateau length.
1156: All other irradiated wires were also studied on the electron beam.
1157: Wires that have been exposed to a charge
1158: of 280~$\frac{mC}{cm~wire}$ were found to be heavily damaged,
1159: showing an efficiency at the level of ~$\sim$1~$\%$-10~$\%$
1160: for the nominal operating high voltage 2.35~kV.
1161: In addition, for all damaged wires the breakdown knee
1162: in the singles rate curves significantly displaced towards lower voltages.
1163: This effect can also be seen for the `reference wire' in Fig. 9.
1164: For the damaged region of this wire,
1165: the breakdown point occurs
1166: at HV=2.45~kV, where the single counting rate increases abruptly.
1167: At the same time, whenever the electrons illuminates regions of the
1168: wire that have not been previously irradiated, no actual difference
1169: in the singles rate curves (before and after irradiation) shows up.
1170:
1171: %In addition, whenever damaged regions of the wires were illuminated with
1172: %electrons, the spurious counting rates (`noise'), ranging from 50~kHz to 500~kHz,
1173: %were observed for all aged wires.
1174: %This effect can be seen for the `reference wire' in Fig. 9. For this wire,
1175: %starting from HV=2.45~kV, spurious spark discharges
1176: %dominate in the single counting rate,
1177: %thus, shifting the breakdown knee towards lower voltages.
1178: % The onset of spurious counting rates
1179: %was every time associated with the appearance of the chamber current
1180: %$\sim~0.1~-~0.2~\mu A$/wire.
1181: %At the same time,
1182: %in the absence of electron beam or whenever the electrons illuminated
1183: %regions of the wire that have not been previously damaged,
1184: %noise counts together with currents were not observed.
1185:
1186:
1187: %\setlength{\unitlength}{1mm}
1188: %\begin{figure}[ph]
1189: % \begin{picture}(160,200)
1190: % \put(50.0,145.0){\special{psfile=fig10.ps vscale=25 hscale=30 } }
1191: % \put(30.0,55.0){\special{psfile=fig11.ps vscale=40 hscale=48 } }
1192: % \put(10.0,-5.0){\special{psfile=fig12.ps vscale=30 hscale=30 } }
1193: % \put(90.0,-10.0){\special{psfile=fig13.ps vscale=35 hscale=35 } }
1194: % \put(0,148){Figure 10: SEM of the 'reference wire' after the accumulated charge of 60~$\frac{mC}{cm~wire}$.}
1195: % \put(0,142){ $C$ and $F$
1196: %elements were identified together with Au signal from the wire material.}
1197: % \put(0,138){ together with Au signal from the wire material.}
1198: % \put(0,78){Figure 11: SEM of the cathode surface composition in the irradiated region }
1199: % \put(20,72){ of the wire after exposure to 280~$\frac{mC}{cm~wire}$. }
1200: % \put(-3,0){Figure 12: Typical deposits on the }
1201: % \put(-4,-6){ anode wire after exposure to 280~$\frac{mC}{cm~wire}$.}
1202: % \put(0,-12){ 240~$\frac{mC}{cm~wire}$. }
1203: % \put(88,0){Figure 13: Wire irradiated over half }
1204: % \put(88,-6){ of its cell width. Deposits built}
1205: % \put(88,-12){up on one side of the wire towards }
1206: % \put(88,-18){all of the primary electrons drifted. }
1207: % \end{picture}
1208: %\caption[kk]{\em }
1209: % \label{fig:point2}
1210: %\end{figure}
1211:
1212: After the beam tests,
1213: the chamber was opened for inspection and both
1214: anode wires and cathodes surfaces were analyzed, using
1215: microscope and later scanning electron microscopy~(SEM).
1216: Observation of all damaged wires
1217: under a microscope show vertically structured black deposits
1218: or 'whiskers'~(see Fig. 12), distributed
1219: randomly within the irradiated area only,
1220: and of up to lengths of 50~$\mu m$ from the wire surface.
1221: The 'whiskers' were found to be very fragile,
1222: and easily broken if touched.
1223: Of special interest, there were two wires at the boundaries of the
1224: irradiated area where only half of the cell width was exposed
1225: to $\alpha$'s. These wires showed significant asymmetries in
1226: the 'whiskers'~(see Fig. 13) with
1227: deposits built up on one side of the anode wire towards
1228: all of the primary electrons drifted.
1229: The observed asymmetries in the anode deposits indicate that
1230: even for high ionization densities produced by $\alpha$-particles,
1231: the operating parameters (high voltage, gas mixture)
1232: led rather to avalanches
1233: well localized on one side of the anode wire rather than to avalanches
1234: whose spread was large enough to surround the wire completely.
1235:
1236: Examination of all damaged wires by SEM
1237: revealed deposits, containing carbon and fluorine
1238: as the only detectable elements,
1239: thus confirming the presence of a polymer coating.
1240: Moreover, carbon and fluorine signals were also identified in the
1241: irradiated regions free of 'whiskers',
1242: together with Au signal from the wire material.
1243: Fig. 10 shows, as an example, the SEM of the `reference wire' after the
1244: accumulated charge of 60~$\frac{mC}{cm~wire}$.
1245: New wires and wires which were exposed to the irradiated gas,
1246: but not irradiated themself, showed peaks only from Au.
1247: Unfortunately, this method is unable to detect hydrogen,
1248: so hydrocarbons registered as a carbon alone and are also
1249: trapped in the polymer coating.
1250: SEM analysis of the cathode surface composition
1251: in the irradiated region of the wire after exposure to
1252: 280~$\frac{mC}{cm~wire}$ was also performed.
1253: Translation of peak areas
1254: into atomic abundances indicates that the top layer of the
1255: cathode consists mainly
1256: of $Al$($>80~\%$) with some traces of carbon and oxygen~(see Fig. 11).
1257:
1258: A direct means of investigating the radiation-initiated spark discharges
1259: was to separate anode and cathode effects by combining new and aged
1260: portions of the tube chamber. When the cathodes of the tubes
1261: that had been previously aged were restrung with the new anode wires,
1262: the breakdown knee in the singles rate displaced to the higher voltages.
1263: %there was no longer an abrupt transition to spurious spark discharges.
1264: Therefore,
1265: one reason for the discharges are some local
1266: deposits on the anode wires~(conductive `whiskers').
1267: %the noise counts can be explained
1268: %as being due to the spikes on the anode wires.
1269: It was reported by Holland~\cite{book3}, that the
1270: properties of polymer films can be electrically
1271: conductive or insulating according to the carbon to hydrogen ratio
1272: and a degree of cross-linking.
1273: If a coating is primarily carbon,
1274: rather than normal polymers, the conductivity will be much higher.
1275: At the same time, the energy and
1276: amount of particle bombardment on the surface can very easily change
1277: the composition and therefore conductivity.
1278: Hydrogen can be easily
1279: removed by ion bombardment, so heavy bombardment leads to a more
1280: carbonaceous than polymer-like deposit, which may be relevant
1281: for the case of irradiation with $\alpha$-particles.
1282:
1283: % During the process of polymer deposition,
1284: %the massive channeling of polymer chains to the least
1285: %resistive regions would produce vertically structured deposits
1286: %that would be identified as 'whiskers'.
1287:
1288: % The results presented in sections 4 and 5,
1289: %demonstrate that the aging rate for irradiation with 5.9~keV $X$-rays and
1290: %100~MeV $\alpha$'s may differs by two orders of magnitude.
1291: % Despite the negligible gas gain loss
1292: %measured after the long-term irradiation with $Fe^{55}$
1293: %$X$-rays, rapid aging effects, observed with $\alpha$-particles,
1294: %completely ruled out $\afh$ (74:20:6) mixture as a possible
1295: %candidate for the operation in the HERA-B high radiation environment,
1296: %where, at least, part of the ionization
1297: %may be deposited by the heavily ionizing particles.
1298: % However, as long as the data from different aging tests can not be combined
1299: %properly, it is very difficult to give an extrapolation about the
1300: %lifetime in the real detector.
1301: % Therefore, in order to find a link between
1302: %results in different setups, we also performed an
1303: %aging studies in the HERA-B environment,
1304: %under conditions as similar as possible to real ones.
1305: % In a subsequent paper we will present the results
1306: %
1307: %The results from these tests are discussed in section 6.
1308:
1309:
1310: %\section{ Aging results in a HERA-B environment.}
1311:
1312: %\subsection{ Aging setup. }
1313:
1314: %\subsection{ Aging in $\afh$(67:30:3) gas mixture.}
1315:
1316: %\subsection{ Aging in $\afo$(65:30:5) gas mixture.}
1317:
1318: %\section{ Discussion of results. }
1319:
1320: %\section{ Further investigations. }
1321:
1322:
1323: \section{ Summary and outlook. }
1324:
1325:
1326: Experimental conditions at HERA-B impose very strong
1327: requirements for the gaseous detectors.
1328: The high radiation load of the HERA-B experiment results in an accumulated
1329: charge of up to 200~$\frac{mC}{cm~wire}$ in the tube chambers. The
1330: chamber signals, which are used to form the trigger, must be collected
1331: in less than the 96~ns between bunch crossings.
1332:
1333: A short description of the criteria which are relevant for the choice of
1334: gases in the HERA-B muon detector are discussed and
1335: the tube chamber characteristics
1336: studied for several $Ar/CF_4$-based mixtures are reported.
1337: However, the main criteria for the choice of the gases are the aging properties.
1338: In this paper, the brief summary of the most recent data
1339: focusing on the binary and ternary mixtures, containing
1340: $Ar$, $CH_4$, $CO_2$ and $CF_4$ is presented.
1341: Although, $CF_4$ gas has been widely used over the last ten years,
1342: the results from it's usage in the drift tubes are quite controversial.
1343: The aging results reported in this paper
1344: demonstrate that the aging rate for irradiation with 5.9~keV $X$-rays and
1345: 100~MeV $\alpha$'s may differ by more than two orders of magnitude.
1346: Despite the negligible gas gain loss
1347: measured after the long-term irradiation with $Fe^{55}$
1348: $X$-rays, rapid aging effects observed with $\alpha$-particles
1349: completely ruled out $\afh$ (74:20:6) mixture as a
1350: candidate for operation in the HERA-B high radiation environment,
1351: where at least part of the ionization
1352: is deposited by heavily ionizing particles.
1353: Moreover,
1354: from these results it is evident that from the accumulated charge alone,
1355: it is not possible to combine the data from the different radiation sources
1356: into one consistent model.
1357: Therefore, as long as the data from different aging tests can not be combined
1358: properly, it is very difficult to give an extrapolation about the
1359: lifetime in the real detector.
1360: In order to find a link between
1361: results in different setups, we also performed
1362: aging studies with $\afh$ (67:30:3)
1363: and $\afo$ (65:30:5) mixtures in the HERA-B environment,
1364: under conditions as similar as possible to real ones.
1365: In a subsequent paper~\cite{hadr} we will report on the results from these tests,
1366: which indicate that the aging rate could also be affected by
1367: the mode of operation, size of the irradiated area and water addition.
1368:
1369:
1370: %\section{ Further investigations. }
1371:
1372:
1373:
1374:
1375: \section*{Acknowledgments.}
1376:
1377: We express our special appreciation for discussions with Dr. J. Va'vra.
1378: We would like to thank Dr. G. Bohm and Wildau
1379: Politechnik Institute for the possibility to analyse the wires.
1380: We thank to K. Reeves and S. Aplin for reading and correcting this
1381: manuscript.
1382:
1383: This work was supported by the
1384: Deutsches Elektronen-Synchrotron (DESY),
1385: by the Alexander von Humboldt-Stiftung and Max Planck Research Award.
1386:
1387:
1388:
1389: %\newpage
1390:
1391: \begin{thebibliography}{99}
1392:
1393: \bibitem{Proposal} T. Lohse $et~al.$, HERA-B collaboration,
1394: An Experiment to Study CP Violation in the B System Using an
1395: Internal Target at the HERA Proton Ring, Proposal,
1396: {\bf DESY-PRC 94/04} (1994).
1397:
1398: \bibitem{TDR} E. Hartouni $et~al.$, HERA-B collaboration,
1399: An Experiment to Study CP Violation in the B System Using an
1400: Internal Target at the HERA Proton Ring, Design Report,
1401: {\bf DESY-PRC 95/01} (1995).
1402:
1403: \bibitem{electronics} M. Buchler $et~al.$,
1404: IEEE Trans. Nucl.Sci., {\bf NS-46 } (1999) 126-132.
1405:
1406: \bibitem{scint} T.J. Sumner {\it et al},
1407: IEEE Trans. Nucl. Sci., {\bf NS-29 (5)} (1982) 1410-1414.
1408:
1409: \bibitem{start} S.A. Korff and R.D.Present,
1410: Phys. Rev. {\bf Vol.65 (9)} (1944) 274-282.
1411:
1412: \bibitem{co2} V. Bawdekar,
1413: IEEE Trans. Nucl. Sci {\bf NS-22 } (1975) 282-285.
1414:
1415: \bibitem{N2} L. Colli, U. Fracchini,
1416: Rev. Sci. Instr. {\bf Vol.23 (1)} (1952) 39-42.
1417:
1418: \bibitem{book1} L.G. Christophorou, Atomic and Molecular
1419: Radiation Physics, (Wiley, New York, 1971)
1420:
1421: \bibitem{fast1} L.G. Christophorou {\it et al},
1422: Nucl. Instr. and Meth. {\bf A 163} (1979) 141-149.
1423:
1424: \bibitem{fast2} L.G. Christophorou {\it et al},
1425: Nucl. Instr. and Meth. {\bf A 171} (1980) 491-495.
1426:
1427: \bibitem{armit} J. C. Armitage {\it et al},
1428: Nucl. Instr. and Meth. {\bf A 271} (1988) 588-496.
1429:
1430: \bibitem{cern} A. Peisert, F. Sauli,
1431: CERN 84-08 (1984).
1432:
1433: \bibitem{biagi} S. Biagi,
1434: Nucl. Instr. and Meth. {\bf A 421} (1999) 234-240.
1435:
1436: \bibitem{cf42} M.C. Borgade {\it et al},
1437: J. Appl. Phys, {\bf Vol.80, (3)} (1996) 1325-1336.
1438:
1439: \bibitem{mix1} T.Yamashita {\it et al},
1440: Nucl. Instr. and Meth. {\bf A 317} (1992) 213-220.
1441:
1442: \bibitem{transport} S.R.Hunter {\it et al},
1443: J. Appl. Phys, {\bf Vol.58, (8)} (1985) 3001-3015.
1444:
1445: \bibitem{christ} L.G. Christophorou {\it et al},
1446: Nucl. Instr. and Meth. {\bf A 309} (1991) 160-168.
1447:
1448: \bibitem{book2} L.G. Christophorou (ed.), Electron-Molecule
1449: Interactions and Their Applications, vols. 1 and 2,
1450: (Academic Press, New York, 1984)
1451:
1452: \bibitem{attach} W.S. Anderson {\it et al},
1453: Nucl. Instr. and Meth. {\bf A 323} (1992) 273-279.
1454:
1455: \bibitem{cf41} L.G. Christophorou {\it et al},
1456: J. Phys. Chem. Ref. Data, {\bf Vol.25, No.5} (1996) 1341-1388.
1457:
1458: \bibitem{quench1} L.G. Piper {\it et al},
1459: J. Chem. Phys, {\bf Vol.59, (6)} (1973) 3323-3340.
1460:
1461: \bibitem{quench2} J.E. Velazco {\it et al},
1462: J. Chem. Phys, {\bf Vol.69, (10)} (1978) 4357-4373.
1463:
1464: \bibitem{becker} U. Becker {\it et al},
1465: Nucl. Instr. and Meth. {\bf A 315} (1992) 14-20.
1466:
1467: \bibitem{grimm} O. Grimm, Diplomarbeit,
1468: University Hamburg, July (1998) (in german)
1469:
1470: \bibitem{beck} M. Beck, Dissertation,
1471: University Rostock, June (1999) (in german)
1472:
1473: \bibitem{mix2} T.Yamashita {\it et al},
1474: Nucl. Instr. and Meth. {\bf A 283} (1989) 709-715.
1475:
1476: \bibitem{gain1} S. Beingessner, R. Carnegie,
1477: Nucl. Instr. and Meth. {\bf A 260} (1987) 210-220.
1478:
1479: \bibitem{charpak} G. Charpak {\it et al},
1480: Nucl. Instr. and Meth. {\bf A 99} (1972) 279-284.
1481:
1482: \bibitem{workshop} Proc. Workshop on Radiation Damage to Wire Chambers,
1483: Lawrence Berkeley Laboratory (Jan. 1986) LBL-21170.
1484:
1485: \bibitem{kadyk} J. A. Kadyk,
1486: Nucl. Instr. and Meth. {\bf A 300} (1991) 436-479.
1487:
1488: \bibitem{vavra} J. Va'vra, ref.~\cite{workshop}, pp. 263-294.
1489:
1490: \bibitem{cern1} R. Bouclier {\it et al},
1491: Aging of microstrip gas chambers: problems and solutions,
1492: CERN-PPE 96-33 (1996).
1493:
1494: \bibitem{gcms} J. Wise {\it et al},
1495: IEEE Trans. Nucl. Sci {\bf NS-37 (2) } (1990) 470-477.
1496:
1497: \bibitem{chemmod} J. Wise {\it et al},
1498: J. Appl. Phys, {\bf Vol.74, (9)} (1993) 5327-5340.
1499:
1500: \bibitem{hess} D. W. Hess, ref.~\cite{workshop}, pp. 15-24.
1501:
1502: \bibitem{yasuda} H. Yasuda, Plasma Polymerization,
1503: (Academic Press, 1985)
1504:
1505: \bibitem{malter} L. Malter
1506: Phys. Review, {\bf Vol. 50} (1936) 48-58.
1507:
1508: \bibitem{juri} I. Juricic, J. Kadyk, ref.~\cite{workshop}, pp. 141-159.
1509:
1510: \bibitem{kott} R. Kotthaus, ref.~\cite{workshop}, pp. 161-193.
1511:
1512: \bibitem{opensh1} R. Openshaw {\it et al},
1513: IEEE Trans. Nucl. Sci {\bf NS-36 (1) } (1989) 567-571.
1514:
1515: \bibitem{algeri} A. Algeri {\it et al},
1516: Nucl. Instr. and Meth. {\bf A 338} (1994) 348-367.
1517:
1518: \bibitem{dissert} V. Pashhoff,
1519: Dissertation, University Freiburg, October (1999)
1520:
1521: \bibitem{lyon} M. Titov,
1522: A Gaseous Muon Detector at the HERA-B experiment,
1523: talk given at Nuclear Science Symposium and Medical Imaging Conference,
1524: 15-20 October 2000, Lyon, France
1525:
1526: \bibitem{hadr} M. Danilov, L. Laptin, I. Tichomirov, M.Titov, Yu. Zaitsev,
1527: Aging of gaseous detectors under high-rate irradiation with
1528: hadronic particles, in preparation.
1529:
1530: \bibitem{tsarnas} N. Spielberg, D. Tsarnas
1531: Rev. Sci. Instr. {\bf Vol.46 (8)} (1975) 1086-1091.
1532:
1533: \bibitem{smith} A. Smith, M. Turner
1534: Nucl. Instr. and Meth. {\bf A 192} (1982) 475-481.
1535:
1536: \bibitem{kollef} M. Kollefrath {\it et al},
1537: Nucl. Instr. and Meth. {\bf A 419} (1998) 351-356.
1538:
1539: \bibitem{kwong} K. Kwong,
1540: Nucl. Instr. and Meth. {\bf A 238} (1985) 265-272.
1541:
1542: \bibitem{atlas} V. Paschhoff, M.Spegel, Aging studies for the
1543: ATLAS MTD's using $Ar/CO_2$(90:10), ATLAS muon note-019 (1999).
1544:
1545: \bibitem{atlasnote} I. Boyko {\it et al}, Aging of aluminum
1546: drift tubes filled with $Ar/CO_2/CH_4$ (92:5:3),
1547: ATLAS muon note-089 (1995).
1548:
1549: \bibitem{sadr} H. Sadrozinski, ref.~\cite{workshop}, pp. 121-129.
1550:
1551: \bibitem{mogab} C. Mogab {\it et al},
1552: J. Appl. Phys, {\bf Vol.49, (7)} (1978) 3796-3803.
1553:
1554: \bibitem{kushner} M.J. Kushner,
1555: J. Appl. Phys, {\bf Vol.53, (4)} (1982) 2923-2938.
1556:
1557: \bibitem{winters} H.F. Winters {\it et al},
1558: J. Appl. Phys, {\bf Vol.48, (12)} (1977) 4973-4983.
1559:
1560: \bibitem{kadyk1} J. Kadyk {\it et al},
1561: IEEE Trans. Nucl. Sci {\bf NS-37 (2) } (1990) 478-486.
1562:
1563: \bibitem{opensh} R. Openshaw {\it et al},
1564: Nucl. Instr. and Meth. {\bf A 307} (1991) 298-308.
1565:
1566: \bibitem{d0} G. Alexeev {\it et al},
1567: Technical design Report for the D0 Forward Muon Tracking
1568: Detector Based on Mini-Drift Tubes, D0 Note 3366, (1997)
1569:
1570: \bibitem{d0note} B. Baldin {\it et al},
1571: Technical design of the central muon system, D0 Note 3365, (1997)
1572:
1573: %\bibitem{stegmann} C. Stegmann, The Outer Tracker of HERA-B,
1574: %Proceedings of 7th International Conference on Instrumentaion for
1575: %Colliding Beam Physics, Hamamatsu'99, Japan (in press)
1576:
1577: \bibitem{hohlmann} M. Hohlmann, The Outer Tracker of HERA-B,
1578: Proceedings of 8th Pisa Meeting on advanced detector,
1579: Isola d'Elba'00, Italy (in press)
1580:
1581: \bibitem{kolanoski} H. Kolanoski, Investigation of Aging
1582: in the HERA-B Outer Tracker Drift Tubes,
1583: talk given at Nuclear Science Symposium and Medical Imaging Conference,
1584: 15-20 October 2000, Lyon, France
1585:
1586: \bibitem{akesson} T. Akesson {\it et al},
1587: Nucl. Instr. and Meth. {\bf A 361} (1995) 440-456.
1588:
1589: \bibitem{straw} ATLAS Technical Design Report, CERN (1997)
1590:
1591: \bibitem{romaniouk} A. Romaniouk,
1592: Choice of materials for the constructio of TRT,
1593: ATLAS Internal Note, INDET-98-211 (1998)
1594:
1595: \bibitem{kriv1} G. Gavrilov {\it et al},
1596: Aging investigation of ATLAS TRT straws, PNPI-preprint-2328 (1999)
1597:
1598: \bibitem{kriv2} T. Ferguson {\it et al},
1599: Possible new mechanism for anode wire aging
1600: in gas filled detectors, PNPI-preprint-2331 (1999)
1601:
1602: \bibitem{beauty} T. Zeuner, The MSGC-GEM Inner Tracker for HERA-B
1603: Nucl. Instr. and Meth. A (Beauty'99 proceedings, in press).
1604:
1605: \bibitem{coyle} J. Va'vra {\it et al},
1606: Nucl. Instr. and Meth. {\bf A 324} (1993) 113-126.
1607:
1608: \bibitem{denisov} D.S. Denisov,
1609: On using $CF_4$ as a working gas for drift tubes (in russian),
1610: IHEP-preprint-90-16 (1990)
1611:
1612: \bibitem{charm} J. DeWulf {\it et al},
1613: Nucl. Instr. and Meth. {\bf A 252} (1986) 443-449.
1614:
1615: \bibitem{straw1} J.Kadyk {\it et al},
1616: Nucl. Instr. and Meth. {\bf A 300} (1991) 511-517.
1617:
1618: \bibitem{argus} M. Danilov {\it et al},
1619: DESY Internal Note 88-090, DESY (1988)
1620:
1621: \bibitem{vavra2} J. Va'vra,
1622: Aging of gaseous detectors, SLAC-PUB-5207 (1990)
1623:
1624: \bibitem{atac} M. Atac, ref.~\cite{workshop}, pp. 55-66.
1625:
1626: \bibitem{gang} AN Ji-Gang {\it et al},
1627: Nucl. Instr. and Meth. {\bf A 267} (1988) 396-407.
1628:
1629: \bibitem{book3} L. Holland, Thin Film Microelectronics
1630: (Chapman and Hall Ltd, 1965) p. 157.
1631:
1632:
1633: \end{thebibliography}
1634:
1635: \end{document}
1636:
1637: