1:
2: \subsection{Interaction trigger counters}
3:
4: Three kinds of interaction-trigger counters (ITC) have been used
5: to trigger p+p inelastic events and find vertices
6: during the Run-2 p+p period. They are Beam-Beam Counters (BBC),
7: Normalization Trigger Counters (NTC) and Zero-Degree Calorimeters (ZDC).
8: Table~\ref{tab:ITC_summary} summarizes acceptance and performance
9: of each ITC.
10: Since trigger efficiency of the ZDC for p+p inelastic events
11: is small (0.01), it was not used for
12: the $J/\psi$ analysis, hence will not be described here.
13: Detailed information on the ZDC is found in \cite{ref:ZDC_NIM}
14: %Trigger efficiencies for ITCs will be discussed in detail
15: %in section~\ref{chap:analysis}.
16:
17: %\renewcommand{\multirowsetup}{\centering}
18:
19: \begin{table}[htbp]
20: \begin{center}
21: \begin{tabular}{|c||c|c|c|c|}\hline
22: Counters & Acceptance & Sensitive particle & Typical &
23: Typical vertex \\
24: & & type & efficiency & resolution (cm) \\ \hline
25:
26:
27: \raisebox{-2.5mm}[0mm][0mm]{BBC}
28: & 3.0$<|\eta|<$3.9
29: & \raisebox{-2.5mm}[0mm][0mm]{charged particles}
30: & \raisebox{-2.5mm}[0mm][0mm]{0.5}
31: & \raisebox{-2.5mm}[0mm][0mm]{2} \\
32: & $\beta>0.7$ & & & \\ \hline
33: NTC & 1.1$<|\eta|<$2.8 & charged particles & 0.6 & 10 \\ \hline
34: ZDC & $|\eta|>$6.2 & neutral particles & 0.01 & 10 \\ \hline
35:
36: \end{tabular}
37: \end{center}
38: \caption[Acceptances and performances of the interaction-trigger counters]
39: {Acceptances and performances of the interaction-trigger
40: counters. Efficiencies and resolutions are for p+p inelastic events.}
41: \label{tab:ITC_summary}
42: \end{table}
43:
44:
45: \input{bbc}
46: \input{ntc}
47: %\input{zdc}
48:
49: