nucl-ex0309003/rhic.tex
1: \section{The Relativistic Heavy-Ion Collider }
2: \indent \label{sec:rhic}
3: 
4: The Relativistic Heavy-Ion collider (RHIC) at Brookhaven National
5: Lab (BNL) is designed to collide counter-rotating heavy-ion beans
6: at energies up to 100 GeV/u.  RHIC is the first facility to
7: collide heavy-ion beams. The center-of-mass energy for these
8: collisions is roughly a factor of ten times greater than the
9: highest energies reached with the previous fixed target heavy-ion
10: experiments. Parameters for existing and future relativistic
11: heavy-ion facilities are given in Table~\ref{tab:colliders}. RHIC
12: consists of two concentric rings of super-conducting magnets
13: (cooled to below 4.6 degrees Kelvin) that focus and guide the
14: beams and a radio frequency ($rf$) system that captures,
15: accelerates and stores the beams. The ring's diameters are
16: approximately 1.22 km.
17: \begin{table}[hbt]
18: \centering\begin{tabular}{lcccccccc} \hline \hline
19:                          & AGS & AGS & SPS & SPS & SPS & RHIC & RHIC & LHC \\
20: \hline
21: Start year               & 1986 & 1992 & 1986 & 1994 & 1999 & 2000 & 2001 & 2006 \\
22: A$_{max}$                & $^{28}$Si & $^{197}$Au & $^{32}$S & $^{208}$Pb & $^{208}$Pb & $^{197}$Au & $^{197}$Au & $^{208}$Pb \\
23: E$_P^{max}$ [AGev]       & 14.6 & 11 & 200 & 158 & 40 & $0.91${\sffamily\footnotesize E}$4$ & $2.1${\sffamily\footnotesize E}$4$ & $1.9${\sffamily\footnotesize E}$7$ \\
24: $\sqrt{s_{_{NN}}}$ [GeV] & 5.4 & 4.7 & 19.2 & 17.2 & 8.75 & 130 & 200 & 6000 \\
25: $\sqrt{s_{_{AA}}}$ [GeV] & 151 & 934 & 614 & $3.6${\sffamily\footnotesize E}$3$ & $1.8${\sffamily\footnotesize E}$3$ & $2.6${\sffamily\footnotesize E}$4$ & $4${\sffamily\footnotesize E}$4$ & $1.2${\sffamily\footnotesize E}$6$ \\
26: $\Delta y/2$             & 1.72 & 1.58 & 2.96 & 2.91 & 2.22 & 4.94 & 5.37 & 8.77 \\
27: \hline \hline
28: \end{tabular}
29: \caption[Heavy-ion colliders] {RHIC compared to existing and
30: future facilities; A$_{max}$ is the maximum species mass number,
31: E$_{P}^{max}$ is the maximum (equivalent) fixed-target beam energy
32: per nucleon, $\sqrt{s_{_{NN}}}$ is the maximum center of mass
33: energy per nucleon, $\sqrt{s_{_{AA}}}$ is the total center of mass
34: energy, and $\Delta y/2$ is the rapidity gap from the beam to
35: mid-rapidity~\cite{raf:let:book}.}\label{tab:colliders}
36: \end{table}
37: 
38: %
39: \begin{figure}[htpb]
40: \centering\mbox{
41: \includegraphics[width=0.9\textwidth]{images/rhic_small.eps}}
42: %\begin{figure}[htbp]
43: %\centerline{\hbox{
44: %\centering\psfig{figure=images/rhic.eps,width=3.0in,clip=t} }}
45: \caption[The BNL--RHIC facility] {A diagram of the Brookhaven
46: National Laboratory collider complex including the accelerators
47: that bring the nuclear ions up to RHIC injection energy (10.8
48: GeV/u for $^{197}$Au$^{79}$).} \label{fig:rhic_injector}
49: \end{figure}
50: %
51: Figure~\ref{fig:rhic_injector} shows the BNL accelerator complex
52: including the accelerators used to bring the gold ions up to RHIC
53: injection energy.  In the first of the Tandem Van de Graaff
54: accelerators, gold ions in a charge state $Q=-1e$ accelerate to 15
55: MeV. The ions then pass through a stripping foil (located between
56: the Van de Graaffs) where electrons are knocked off so that their
57: most probable charge state becomes $Q=+12e$. With their charge
58: changed from negative to positive, the ions gain another 1 MeV/u
59: of energy as they accelerate through the second Van de Graff, back
60: to ground potential. On exiting the Tandem, the ions pass through
61: a second stripping foil bringing their most probable charge to
62: $Q=+32e$. They are then injected into the Booster synchrotron and
63: accelerated to 95 MeV/u. A stripper foil in the transfer line
64: between the booster and the Alternating Gradient synchrotron (AGS)
65: increases their charge state to $Q=+77e$. In the AGS the ions are
66: accelerated to 10.8 GeV/u. They are extracted from the AGS and
67: passed through one final stripper foil where the remaining K-shell
68: electrons are removed ($Q=+79e$). Finally, they are injected into
69: RHIC where they are accelerated to top energy and can be stored
70: for up to 10 hours. Table~\ref{tab:rhic_specs} lists important
71: parameters for RHIC.
72: 
73: \begin{table}[hbt]
74: \centering\begin{tabular}{lc} \hline \hline
75: Top Au+Au $\sqrt{s_{_{NN}}}$          & 200 GeV\\
76: Ave. luminosity $\mathcal{L}$ (10 hour store)  & $\sim 2 \times 10^{26}$ cm$^{-2}$s$^{-1}$ \\
77: Bunches per ring                         & 60 \\
78: Gold ions per bunch                      & $10^9$ \\
79: Crossing points                          & 6 \\
80: Beam lifetime (store length)             & $\sim 10$ hours \\
81: RHIC circumference                       & 3833.845 m \\
82: \hline \hline
83: \end{tabular}
84: \caption[RHIC parameters] {Nominal RHIC parameters for Au+Au
85: collisions.} \label{tab:rhic_specs}
86: \end{table}
87: 
88: 
89: %\begin{figure}[htbp]
90: %\centerline{\hbox{
91: %\centering\psfig{figure=images/arcdipole.eps,width=4.in,clip=t}
92: %}}
93: %\caption[Cross section of an arc dipole]
94: %{Cross section of an arc dipole. The outer diameter of the
95: %vacuum vessel is 610 millimeters.}
96: %\label{fig:arcdipole}
97: %\end{figure}
98: %
99: 
100: 
101: \section{RHIC Experimental Program} \indent
102: 
103: To date, RHIC has generated collisions between gold nuclei at
104: $\sqrt{s_{_{NN}}} =$ 22, 56, 130, and 200 GeV, between protons at
105: $\sqrt{s_{_{NN}}} = 200$ GeV, and between gold and deuterium
106: nuclei at $\sqrt{s_{_{NN}}} = 200$ GeV.
107: Table~\ref{tab:rhic_performance} shows the luminosity achieved at
108: the end of RHIC Run-2 (Au+Au collisions at $\sqrt{s_{_{NN}}} =
109: 200$~GeV). The STAR experiment recorded integrated luminosities
110: $\mathcal{L} \sim 2.8 \:b^{-1}$ and $\mathcal{L} \sim 80 \:\mu
111: b^{-1}$ for RHIC Run-1 (Au+Au collisions at $\sqrt{s_{_{NN}}} =
112: 130$~GeV) and RHIC Run-2 respectively. Most of the integrated
113: luminosity comes late in the runs, after the collider is tuned.
114: \begin{table}[hbt]
115: \centering\begin{tabular}{ccccc} \hline \hline
116: Bunches & Ions/Bunch & $\mathcal{L}_{peak}$ & $\mathcal{L}_{ave}$ (store) & Integrated \\
117:  {} &  {} &  {[cm$^{-2}$s$^{-1}$]} &  {[cm$^{-2}$s$^{-1}$]} &  {$\mathcal{L}$ [($\mu$b)$^{-1}$]} \\
118: \hline
119: 55 & $6 \times 10^8$ & $3.7 \times 10^{26}$ & $3.7 \times 10^{26}$ & $\sim 80$ \\
120:  \hline \hline
121: \end{tabular}
122: \caption[RHIC Run-2 performance] {The performance of RHIC during
123: the 2001 Au+Au run (Run-2).} \label{tab:rhic_performance}
124: \end{table}
125: 
126: 
127: There are four experimental collaborations at RHIC; the PHOBOS
128: collaboration with 107 members from 8 institutions, the BRAHMS
129: collaboration with 51 members from 14 institutions, the PHENIX
130: collaboration with 328 members from 52 institutions, and the STAR
131: collaboration with 293 members from 39
132: institutions~\footnote{These numbers are taken from each
133: collaborations author list as of July 2003 and do not represent
134: the total number of people working on the experiment. There are,
135: for example, over 450 scientist and engineers working on the
136: PHENIX experiment.}.
137: %The PHOBOS detector system consists of a cylindrical array of
138: %silicon detectors and two movable spectrometer arms. The BRAHMS
139: %detector consists of a forward spectrometer and a mid rapidity
140: %spectrometer.
141: 
142: \begin{table}[htpb]
143: \centering\begin{tabular}{|p{66mm}|p{66mm}|} \hline
144: %
145: \epsfig{file=images/phenix_event_small.eps, width=60mm} &
146: %
147: \epsfig{file=images/star_event_small.eps, width=60mm} \\
148: \multicolumn{1}{|c|}{\textbf{PHENIX event display}} &
149: \multicolumn{1}{c|}{\textbf{STAR event display}} \\
150: \hline
151: %
152: Two muon spectrometers cover the pseudo-rapidity region $1.1 <
153: |\eta| < 2.4$ and azimuth angle $0 < \phi < 2\pi$. A central
154: spectrometer with two arms and tracking sub-systems (each
155: subtending $\pi/2$ radians) covers $|\eta| < 0.35$. With a smaller
156: acceptance and faster detectors the emphasis is on triggering on
157: rarer probes, hadron identification and electron identification.
158: %
159: & A large acceptance solenoidal tracking detector with particle
160: identification covers the full azimuth ($|\phi|<\pi$), $|\eta| <
161: 2.0$ and $2.5< |\eta| < 4.0$. Subsystems include a central TPC,
162: two forward TPCs, a silicon vertex tracker and a barrel
163: electromagnetic calorimeter. The emphasis is on global event
164: characterization, resonance identification, fluctuations and
165: event-by-event variables.
166: %
167: \\
168: \hline
169: %
170: \epsfig{file=images/phobos_event_small.eps, width=60mm} &
171: %
172: \epsfig{file=images/brahms_event_small.eps, width=55mm} \\
173: \multicolumn{1}{|c|}{\textbf{PHOBOS event display}} & \multicolumn{1}{c|}{\textbf{BRAHMS detector}} \\
174: \hline
175: %
176: Measurements of charged particles are made across a full
177: solid-angle with a multiplicity detector. Two small acceptance
178: spectrometer arms allow for particle identification at
179: mid-rapidity. Multiplicity measurements across a broad range of
180: $\eta$ and $p_T$ are emphasized.
181: %
182: & Designed to provide good particle identification across a broad
183: rapidity and $p_T$ range ($0<y<4$; $0.2 < p_T < 3.0$~GeV/c) with
184: two small solid-angle spectrometers. Measuring particle production
185: at forward angles is emphasized.
186: %
187: \\
188: \hline
189: \end{tabular}
190: \caption[RHIC experiments] {Summary of RHIC experiments.}
191: \label{tab:rhic_detectors}
192: \end{table}
193: 
194: In this thesis we present an analysis of Au+Au collisions recorded
195: by the STAR detector during the summer of 2000 and the winter of
196: 2001. Approximately $5 \times 10^5$ and $5 \times 10^6$ usable
197: events were recorded at $\sqrt{s_{_{NN}}} = 130$~GeV and
198: $\sqrt{s_{_{NN}}} = 200$~GeV respectively.
199: 
200: \clearpage
201: