1: %
2: \section{Data \& data analysis}\label{analysis}
3: %
4: The results presented here utilize data obtained by the PHENIX collaboration for
5: the Au+Au and Cu+Cu colliding systems at $\sqrt{s_{NN}}$=200 GeV. A detailed
6: description of the PHENIX detector is given elsewhere~\cite{nim_1}. The procedures
7: for tracking and event selection are described in Refs.~\cite{Adler:2003kt,Adler:2004cj}.
8: The azimuthal anisotropies relevant to this work were measured using the reaction
9: plane method \cite{Danielewicz:1985hn,Poskanzer:1998yz,Ollitrault:1993ba}. This method
10: measures the correlations between the azimuthal angle of the particles detected
11: in the central arms of PHENIX and the azimuth of the reaction plane obtained with
12: the two Beam-Beam Counters (BBC) located at $\mid{\eta}\mid \sim 3 - 3.9$
13: \cite{Adler:2003kt}. An important advantage of the large $\eta$ separation between
14: the BBC's and the central arms of PHENIX is the expectation that the evaluation of the
15: azimuth of the reaction plane is much less affected by possible non-flow
16: contributions, especially those due to jets\cite{Adler:2003kt}.
17:
18: The magnitude of these elliptic flow correlations was determined
19: by evaluating the second Fourier coefficient $v_2$, of the azimuthal distribution
20: of emitted particles relative to the azimuth of the reaction plane
21: \cite{Danielewicz:1985hn,Poskanzer:1998yz,Ollitrault:1993ba}:
22: %
23: \begin{equation}
24: %
25: v_2\equiv\langle e^{2i(\phi-\Phi_{RP})}\rangle
26: =\langle \cos 2(\phi-\Phi_{RP})\rangle.
27: \label{rxn_plane}
28: %
29: \end{equation}
30: %
31: Here, $\phi$ is the azimuthal angle of a particle measured in the laboratory
32: coordinate system and $\Phi_{RP}$ is an estimate of the azimuth of the reaction
33: plane. A resolution factor was evaluated and used to correct for the dispersion of
34: the measured reaction plane about the true reaction plane.
35:
36: Detailed measurements were performed over a broad range of centralities, $p_T$ and
37: particle species. The results from these measurements are presented in the following
38: sections.
39: