1: \section{Gas System}
2:
3: The drift velocity of the counting gas has to be large because of
4: the 96\,ns time distance between bunches and the requirement
5: to register events within this time.
6: With a gas mixture containing a sufficient
7: fraction of the fast gas component CF$_4$,
8: drift velocities of up to 150\,$\mu$m/ns are reached \cite{grimm}.
9: After studies of aging and etching properties with
10: different gas mixtures like CF$_4$/CH$_4$, Ar/CF$_4$/CH$_4$ and
11: Ar/CF$_4$/CO$_2$ \cite {otr_aging}, the latter mixture was
12: chosen with a volume ratio of 65\,$\%$/30\,$\%$/5\,$\%$.
13:
14: \begin{figure}
15: \epsfig{file=pictures/gas_scheme.eps,width=10cm,
16: height=8cm}
17: \caption{Schematical view of the OTR gas system.}
18: \label{fig:gas_scheme}
19: \end{figure}
20:
21: The total volume of all OTR chambers is about 22\,m$^3$.
22: Because of the high cost of CF$_4$ and also for environmental
23: reasons, it is necessary to use a closed-loop gas system.
24: The block diagram in Fig.\ \ref{fig:gas_scheme} shows the
25: functionality.
26: The circuit consists of the following components:
27: A 1.5\,m$^3$ storage tank where fresh gas coming from
28: the mixing station is added to the circulation, the purification system,
29: the distribution station which regulates the gas flow into
30: the 26 chambers, and the pump station with 15 metal bellow
31: pumps which circulate the gas.
32: Both, gas flow and pressure are regulated and controlled with help of
33: a programmable logic controller for the
34: pressure transducers and mass flow controllers.
35: The flow rate through the system is 20\,m$^3$/h, i.e. almost
36: one volume exchange per hour.
37: The gas enters a chamber through a distribution pipe at the bottom,
38: flows through the cells of the modules, and leaves the gas box at
39: the top. In order to minimize air intake through leaks in the gas boxes,
40: the pressure in all chambers is kept at 0.5\,mbar above atmospheric
41: pressure.
42: A safety tank filled with counting gas is acting as a buffer volume
43: to minimize air intake in an alarm situation
44: when the regulation is switched off and the chambers open to the
45: outside via safety valves and safety tank.
46: A detailed description of the gas system and its performance is
47: given in \cite{hohlmann}.
48:
49: \paragraph{Gas Storage and Mixing:}
50: There are two 450-liter gas storage reservoirs filled with
51: liquid Argon and with CO$_2$, respectively, and a 600-liter
52: tank for CF$_4$.
53: The gases flow into the mixing station in ratios
54: controlled by gas flow regulators and then into the storage tank.
55: In case of the first fill or for a longer shut-down period,
56: a cheaper Ar/CO$_2$ mixture is used to remove the air or
57: to prevent that air enters the closed-loop system.
58: With addition of the CF$_4$ component one obtains the proper
59: working gas mixture within several days.
60: During data taking about 0.5\,to\,2\,$\%$ fresh gas per volume
61: exchange is continuously added to the circulating gas.
62: This results in a CF$_4$ consumption of about 400\,kg/month.
63: The required tolerances for the gas composition are 65$\pm$1$\%$,
64: 30$\pm$1$\%$ and 5$\pm$0.2$\%$ for Argon, CF$_4$ and CO$_2$,
65: respectively.
66:
67: \paragraph{Purification Station:}
68: Before the gas is distributed to the different chambers, it
69: is purified by removing oxygen and water.
70: There are two regenerable purifier stations installed, both
71: containing ~60\,kg of catalyst R3-11G \cite{purifier}. While one of
72: them is in operation, the other station is excluded
73: from the closed-loop circuit for regeneration.
74: About every 10 days the stations are switched.
75: This guarantees a continuous gas purification keeping the oxygen
76: content below 200\,ppm and the water level below 20\,ppm.
77: Mainly due to residual air in the system and because of
78: small leaks, there is a non-negligible fraction of nitrogen
79: in the counting gas.
80: The nitrogen level is kept below 2000\,ppm by continuously venting
81: a small fraction of the circulating gas and by adding a corresponding
82: amount of fresh gas.
83:
84: Trace contaminants in the counting gas were suppressed by strictly
85: avoiding the use of outgassing materials in fittings, seals, pumps
86: etc. Stainless steel and flexible metal tube piping was used
87: throughout the system.
88:
89: \paragraph{Gas Analysis for Quality Control:}
90: The system continuously analyses the gas by measuring the fractions
91: of the three main components and of certain impurities like
92: oxygen, nitrogen and water. The common input after purification
93: and all output lines from the 26 chambers can be connected
94: via a programmable switch to the gas analysis station which
95: consists of a gas chromatograph, an oxygen meter and a moisture
96: meter. Each measurement takes about 10 minutes, i.e. after 4.5 hours
97: a given line is measured again.