physics0507048/gas.tex
1: \section{Gas System}
2: 
3: The drift velocity of the counting gas has to be large because of 
4: the 96\,ns time distance between bunches and the requirement 
5: to register events within this time. 
6: With a gas mixture containing a sufficient
7: fraction of the fast gas component CF$_4$, 
8: drift velocities of up to 150\,$\mu$m/ns are reached \cite{grimm}. 
9: After studies of aging and etching properties with 
10: different gas mixtures like CF$_4$/CH$_4$, Ar/CF$_4$/CH$_4$ and
11: Ar/CF$_4$/CO$_2$ \cite {otr_aging}, the latter mixture was 
12: chosen with a volume ratio of 65\,$\%$/30\,$\%$/5\,$\%$. 
13: 
14: \begin{figure}
15:    \epsfig{file=pictures/gas_scheme.eps,width=10cm,
16:      height=8cm}
17:    \caption{Schematical view of the OTR gas system.}
18:    \label{fig:gas_scheme}
19: \end{figure}
20: 
21: The total volume of all OTR chambers is about 22\,m$^3$.
22: Because of the high cost of CF$_4$ and also for environmental 
23: reasons, it is necessary to use a closed-loop gas system. 
24: The block diagram in Fig.\ \ref{fig:gas_scheme} shows the 
25: functionality.
26: The circuit consists of the following components: 
27: A 1.5\,m$^3$ storage tank where fresh gas coming from 
28: the mixing station is added to the circulation, the purification system, 
29: the distribution station which regulates the gas flow into
30: the 26 chambers, and the pump station with 15 metal bellow
31: pumps which circulate the gas.
32: Both, gas flow and pressure are regulated and controlled with help of 
33: a programmable logic controller for the 
34: pressure transducers and mass flow controllers.
35: The flow rate through the system is 20\,m$^3$/h, i.e. almost 
36: one volume exchange per hour.
37: The gas enters a chamber through a distribution pipe at the bottom, 
38: flows through the cells of the modules, and leaves the gas box at 
39: the top. In order to minimize air intake through leaks in the gas boxes, 
40: the pressure in all chambers is kept at 0.5\,mbar above atmospheric
41: pressure.
42: A safety tank filled with counting gas is acting as a buffer volume
43: to minimize air intake in an alarm situation 
44: when the regulation is switched off and the chambers open to the 
45: outside via safety valves and safety tank.
46: A detailed description of the gas system and its performance is 
47: given in \cite{hohlmann}.
48:  
49: \paragraph{Gas Storage and Mixing:} 
50: There are two 450-liter gas storage reservoirs filled with 
51: liquid Argon and with CO$_2$, respectively, and a 600-liter 
52: tank for CF$_4$. 
53: The gases flow into the mixing station in ratios
54: controlled by gas flow regulators and then into the storage tank.
55: In case of the first fill or for a longer shut-down period,  
56: a cheaper Ar/CO$_2$ mixture is used to remove the air or 
57: to prevent that air enters the closed-loop system.
58: With addition of the CF$_4$ component one obtains the proper 
59: working gas mixture within several days.
60: During data taking about 0.5\,to\,2\,$\%$ fresh gas per volume
61: exchange is continuously added to the circulating gas.
62: This results in a CF$_4$ consumption of about 400\,kg/month.
63: The required tolerances for the gas composition are 65$\pm$1$\%$, 
64: 30$\pm$1$\%$ and 5$\pm$0.2$\%$ for Argon, CF$_4$ and CO$_2$, 
65: respectively.
66: 
67: \paragraph{Purification Station:}
68: Before the gas is distributed to the different chambers, it
69: is purified by removing oxygen and water. 
70: There are two regenerable purifier stations installed, both 
71: containing ~60\,kg of catalyst R3-11G \cite{purifier}. While one of 
72: them is in operation, the other station is excluded 
73: from the closed-loop circuit for regeneration. 
74: About every 10 days the stations are switched. 
75: This guarantees a continuous gas purification keeping the oxygen 
76: content below 200\,ppm and the water level below 20\,ppm.  
77: Mainly due to residual air in the system and because of 
78: small leaks, there is a non-negligible fraction of nitrogen 
79: in the counting gas. 
80: The nitrogen level is kept below 2000\,ppm by continuously venting 
81: a small fraction of the circulating gas and by adding a corresponding 
82: amount of fresh gas. 
83: 
84: Trace contaminants in the counting gas were suppressed by strictly
85: avoiding the use of outgassing materials in fittings, seals, pumps
86: etc. Stainless steel and flexible metal tube piping was used
87: throughout the system.
88: 
89: \paragraph{Gas Analysis for Quality Control:}
90: The system continuously analyses the gas by measuring the fractions 
91: of the three main components and of certain impurities like 
92: oxygen, nitrogen and water. The common input after purification 
93: and all output lines from the 26 chambers can be connected
94: via a programmable switch to the gas analysis station which 
95: consists of a gas chromatograph, an oxygen meter and a moisture
96: meter. Each measurement takes about 10 minutes, i.e. after 4.5 hours 
97: a given line is measured again.
98: 
99: %%% Local Variables: 
100: %%% mode: latex
101: %%% TeX-master: "commission.txt"
102: %%% End: 
103: