physics0609201/bibl.tex
1: %%%=======================================================
2: %%% =
3: %%% = Sample layout file for the class "aipproc"
4: %%% = 
5: %%% = DO NOT USE THIS FILE AS A TEMPLATE FOR YOUR DOCUMENTS
6: %%% =
7: %%% = Instead use the file template-xx.tex
8: %%% =
9: %%%=======================================================
10: 
11: 
12: \input{aipcheck.tex}
13: 
14: \newcommand\sps{\space\space\space\space}
15: \typeout{}
16: \typeout{!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!}
17: \typeout{!! \sps\sps\sps\sps\sps\sps\sps\sps\sps\sps\sps\sps!!}
18: \typeout{!! This is *NOT* a template file for producing \sps!!}
19: \typeout{!! new documents. \sps\sps\sps\sps\sps\sps\sps\sps\space!!}
20: \typeout{!!\sps\sps\sps+---------------+\sps\sps\sps\sps\sps!!}
21: \typeout{!! Please use |template-xx.tex| for this purpose! \space!!}
22: \typeout{!!\sps\sps\sps+---------------+\sps\sps\sps\sps\sps!!}
23: \typeout{!! (the 'xx' depends on the distribution) \sps\sps\space!!}
24: \typeout{!! \sps\sps\sps\sps\sps\sps\sps\sps\sps\sps\sps\sps!!}
25: \typeout{!! This file is for testing and displaying the \sps!!}
26: \typeout{!! AIP layouts only. \sps\sps\sps\sps\sps\sps\sps\space\space!!}
27: \typeout{!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!}
28: \typeout{}
29: 
30: 
31: \typeout{}
32: \typeout{**********************************************}
33: \typeout{*}
34: \typeout{* Here you can type in any options for the class.}
35: \typeout{* A full list of supported options is described in}
36: \typeout{* the aipguide documentation.}
37: \typeout{*}
38: \typeout{* Or you may simply press the <RETURN> key in which}
39: \typeout{* case the file is processed with the standard settings.}
40: \typeout{*}
41: \typeout{**********************************************}
42: \typeout{}
43: %\typein[\selectedoptions]{Any options to the class?}
44: %\ifx\empty\selectedoptions
45: %  \def\selectedoptions{final}
46: %\fi
47: \def\selectedoptions{final}
48: 
49: \documentclass[
50:    \selectedoptions
51:   ]
52:   {aipproc}
53: 
54: 
55: 
56: \newcommand\sample{%
57:  Infandum, regina, iubes renovare dolorem, Troianas ut opes et
58:  lamen\-ta\-bile regnum cruerint Danai; quaeque ipse miserrima vidi, et
59:  quorum pars magna fui. Quis talia fando Myrmidonum Dolopumve aut duri
60:  miles Ulixi temperet a lacrimis? \smallsample
61: }
62: 
63: \newcommand\smallsample{%
64:  Et iam nox umida caelo praecipitat,
65:  suadentque cadentia sidera somnos.
66:  Sed si tantus amor casus cognoscere
67:  nostros et breviter Troiae supremum audire laborem, quamquam animus
68:  meminisse horret, luctuque refugit, incipiam.
69: }
70: 
71: \typeout{}
72: \typeout{**********************************************}
73: \typeout{*}
74: \typeout{* Type in the layout style name to be used:}
75: \typeout{*}
76: \typeout{* `6x9' for AIP proceedings 6x9 inch single column}
77: \typeout{* `8x11single' for AIP proceedings 8x11 inch single column}
78: \typeout{* `8x11double' for AIP proceedings 8x11 inch double column}
79: \typeout{* `arlo' for Acoustics Research Letters Online}
80: \typeout{*}
81: \typeout{* ATTENTION:}
82: \typeout{*}
83: \typeout{* \space Typesetting the guide with different styles might
84:                   produce}
85: \typeout{* \space errors if the .aux file is kept between runs!}
86: \typeout{*}
87: \typeout{**********************************************}
88: \typeout{}
89: %\typein[\selectedlayoutstyle]{What layout?}
90: \def\selectedlayoutstyle{6x9}
91: \layoutstyle\selectedlayoutstyle
92: 
93: \SetInternalRegister\hbadness{8000} % pseudo latin isn't breaking very well :-)
94: 
95: 
96: % We need something to show special stuff for ARLO only.
97: %
98: \newcommand\doingARLO[2][]{%
99:   \ifx\mmref\undefined #1\else #2\fi
100: }
101:   
102: 
103: \begin{document}
104: 
105: \title 
106:       [Infandum, regina, iubes renovare dolorem]
107:       {Performance of the PRIMEX Electromagnetic Calorimeter}
108: 
109: %\classification{43.35.Ei, 78.60.Mq}
110: \classification{}
111: \keywords{calorimeter, photon, energy resolution}
112: 
113: \author{M.Kubantsev}{
114:   address={Institute of Theoretical and Experimental Physics, 
115: Moscow, Russia/Northwestern University, Evanston, Il 60208, USA},
116:   email={kubants@fnal.gov}
117: }
118: 
119: \iftrue
120: \author{I. Larin}{
121:   address={Institute of Theoretical and Experimental Physics, 
122: Moscow, Russia},
123:   email={larin@itep.ru},
124: }
125: 
126: \author{A. Gasparyan}{
127:   address={Physics Department NC A\&T State University Greensboro, NC 27411, USA},
128:   email={david@dcarlisle.demon.co.uk},
129: }
130: \fi
131: 
132: % \copyrightholder{Acoustical Scociety of America}
133: \copyrightyear  {2001}
134: 
135: 
136: 
137: \begin{abstract}
138: \normalsize
139: We report the design and performance of the hybrid 
140: electromagnetic calorimeter for the PRIMEX experiment 
141: at Jefferson Laboratory. The detector was designed,
142: constructed and used for high precision measurement
143: of the lifetime of the neutral pion via the Primakoff
144: effect. Calorimeter installation and commissioning was 
145: completed with first physics run in fall of 2004. 
146: Especially we present calorimeter energy and position 
147: resolution at the transition region between PWO crystals 
148: and lead glass.     
149: \end{abstract}
150: 
151: 
152: \date{2006/07/05}
153: 
154: 
155: \maketitle
156: 
157: \bigskip
158: 
159: \section{Introduction}
160: 
161: 
162:   Measurement of the partial width of the 
163:   decay $\pi^{0} \to \gamma\gamma$ provides an unique test of low energy 
164:   QCD in confinement scale  regime. The experiment PRIMEX (Primakoff
165:   Experiment) \ref{prop}  was designed to 
166:   make a high precision (one percent level) measurement of this decay.
167:   Tagged photon beam at Hall B of the Jefferson Laboratory was used for 
168:   forward production of neutral pions in the Coulomb field of the target 
169:   nucleus (Primakoff effect). The two photons from the pion decay are 
170:   detected in the Hybrid Calorimeter (HYCAL). The HYCAL was designed to 
171:   provide high efficiency registration of the photons with high resolution 
172:   in energy and space. In present talk we describe physics requirements 
173:   for calorimeter, design and construction of the setup, calibration and
174:   performance during the physics data taking. We summarize calorimeter 
175:   characteristics in the conclusion.
176: 
177: \section{Physic Requirements}
178:  As we measure absolute value of the cross section
179:   high photon efficiency is essential for precise measurements as well as accurate 
180:   monitoring of the tagged photon beam. The Primakoff production cross section 
181:   is peaked at  $~0.3 mrad$ for nucleon target at energies of this experiment
182:  ($E_{\gamma} = 4.9 - 5.5 GeV$). 
183:  \newpage
184:  High angular and energy resolutions are required to cleanly distinguish the 
185:  Primakoff mechanism from $\pi^{0}$ production by other processes, and good 
186:  invariant mass reconstruction is essential for rejection of backgrounds. 
187:   
188:  
189:   Using Intensive Monte Carlo studies and data from the beam test of the
190:    prototypes we formulated requirements for the calorimeter performance:
191:    
192:   $\gamma\gamma$ invariant mass  resolution is to be better than 2.5 $MeV/c^2$
193:   
194:   angular resolution for reconstructed $\pi^0$ is better than 0.35 mrad.
195: 
196: \section{Design of the Calorimeter}
197:  We have chosen a hybrid calorimeter scheme where the central 
198:  part of the detector is made of high resolution scintillating crystals 
199:  with a hole in the middle for the passage of the photon beam and the  
200:  peripheral part is consisting of lead glass Cherenkov modules.To ensure 
201:  high performance of the calorimeter the central part of the detector 
202:  was constructed from 1152 lead tungstate (PWO) scintillating crystals 
203:  surrounded with 576 lead glass blocks. The transverse dimensions of the 
204:  HYCAL ($116 x116 cm^2$) were chosen to have sufficient geometrical 
205:  acceptance with fixed central hole ($4 x 4 cm^2$) in 
206:  the middle of the detector.This design is based on an optimization of the 
207:  cost and performance of the calorimeter.
208:  It allows us to have maximal efficiency for $\pi^0$ decay photons without
209:  prohibitive cost of the large area crystal calorimeter. 
210:  At a distance of 7.3 m from the production 
211:  target, the calorimeter has about 70\% geometrical acceptance for forward 
212:  neutral pions.
213:  Since the area 
214:  around the photon beam is under high rate irradiation the crystals used should 
215:  be radiation hard. The
216:  best crystals available now are lead tungstate ($PbWO_4$) which were developed 
217:  for the CMS Electromagnetic Calorimeter Collaboration at Russia and China. 
218:  Since the Russian crystal production is saturated by LHC experiments
219:  under construction we worked with Shanghai Institute of Ceramics which 
220:  provided the crystals of high quality under our strict specifications. 
221:  The crystals dimensions of 20.5 x 20.5 x 180 $mm^3$ were chosen.
222:  The individual crystals were wrapped in 100 ${\mu}m$ VM2000 sheets. The crystals were 
223:  viewed by the Hamamatsu R4125HA photomultiplier tubes coupled to them with optical 
224:  grease. As the PWO crystal light yield is highly temperature dependent 
225:  (~2\%/${\deg}C$ at room temperature) and increasing with decrease of temperature, so 
226:  temperature stabilization of the calorimeter is mandatory.  
227:  The operational temperature was chosen to be 14$^{0}C$ using cooled water circulation 
228:  through tubes installed in the outer body of the calorimeter to provide 
229:  thermal stabilization. 
230:  
231:  The lead glass modules supplied by IHEP (Serpukhov, Russia) with 
232:  dimensions 38 x 38 x450 $mm^2$ were made from the same type of glass 
233:  used in many experiments at high energies and in the Jefferson Laboratory 
234:  and its properties are well known. The lead glass blocks are wrapped in 25 
235:  ${\mu}m$ aluminized Mylar foil. The Cherenkov light produced in lead 
236:  glass radiator is detected by The FEU-84-3 photomultiplier tube. 
237:  
238:  
239:  The photograph of the detector during assembly is shown in Fig.~\ref{fig:calpix}
240:  The HYCAl calorimeter on its support stand in the run configuration is 
241:  shown in Fig.~\ref{fig:cal1a}
242: \clearpage
243: 
244: \begin{center}
245: \begin{figure}
246: \caption{Photograph of the HYCAL calorimeter during assembly: 
247: crystal and lead glass arraysare shown}
248: \label{fig:calpix}
249: \includegraphics[angle=270,width=0.5\textwidth]{hycal_pix.eps}
250: \end{figure} 
251: 
252: \begin{figure}[!h]
253: %\includegraphics[angle=270,width=1.0\textwidth]{cal11a.eps}
254: \caption{Scheme of the HYCAL calorimeter}
255: \label{fig:cal1a}
256: \special{psfile=cal11a.eps
257: hoffset=-200
258: voffset=0
259:  hscale=50
260:  vscale=50
261:  angle=270}
262: 
263: \end{figure} 
264: \end{center}
265: 
266: \vspace{10.0cm}
267: 
268:  The PrimEx DAQ system read out over 2200 channels of ADC and TDC and utilize 
269:  a CODA based Fastbus system with Trigger Supervisor module. A big advantage 
270:  of this system (see Fig.~\ref{fig:electr}) is the ability to operate in fully 
271:  buffered mode. Namely, events are buffered in the digitization modules themselves
272:  allowing the modules to be "live" during readout. This significantly reduce the 
273:  dead time of the experiment. It is particularly important to have a low dead time 
274:  for the absolute cross section measurements of the $\pi^{0}$ Primakoff production.
275: 
276: \section{Calibration}
277: 
278: 
279: To make possible calibration of all modules of the calorimeter with 
280: photon beam, the HYCAL is assembled in a steel box in the calorimeter frame.
281: To do this the entire assembly with weight of about five tons is movable in 
282: both horizontal and vertical directions with position accuracy of 
283: $\pm 0.7 mm$. A transporter has been designed and built to provide 
284: movement of the entire assembly with support frame, thermo-stabilization 
285: system light monitoring and the delay cables. The calorimeter position is 
286: remotely movable during calibration, so each module positioned in the beam.
287: 
288: In order to maintain high performance of the calorimeter, periodic energy 
289: calibration with tagged photon beam is required. As this procedure may take 
290: significant beam time and can not be performed often, so an optical monitorting
291: system is used meantime as relative calibration.
292: The Light Monitoring System consists of the following main parts: a light source,
293: a light mixing box, a light distribution system, reference detectors with DAQ
294: system.  The light source comprises an assembly of NICHIA super bright blue LEDs 
295: (peak wavelenght 470 nm). Light mixing is done using a six inch diameter 
296: integrating sphere  (ORIEL) providing 2000 distribution channels. Light is distributed
297: to the individual calorimeter modules via a bundle of plastic fibers. Each fiber 
298: is attached to the front face of the individual detector module. As a reference stable 
299: detector a HAMAMATSU PIN photodiode (S3399, 3 mm diameter) with AMPTEC 
300: low noise charge amplifier was used. Light from the light monitoring system is 
301: periodically injected into the detector modules between real events during data 
302: taking.  
303: \begin{center}
304: \begin{figure}
305: \includegraphics[angle=0,width= 0.7\textwidth]{crystal_res.eps}
306: \caption{Energy resolution of the PWO crystals}
307: \label{fig:pwor}
308: \end{figure}
309: \begin{figure}
310: \includegraphics[angle=0,width=0.7\textwidth]{glass_res.eps}
311: \caption{Energy resolution of the lead glass}
312: \label{fig:lgr}
313: \end{figure} 
314: \end{center}
315: 
316: Tagged photon beam irradiated each module of the calorimeter during 
317: calibration runs. A "snake scan" scheme was used. After calibration 
318: relative gains of the modules 
319: and energy resolution of the detector are found.   
320: Measured dependence of energy resolution on photon energy for PWO and lead 
321: glass parts of the detector are shown in Fig.~\ref{fig:pwor} and 
322: Fig.~\ref{fig:lgr}.
323: 
324: The final fine-tuning of the modules gains was made using photons from decays of 
325: neutral pions observed in the experiment.
326:  
327: 
328: \clearpage
329: 
330: \section{Physics Run performance}
331: 
332: The experiment has took physics data in November 2004. Several exposures with 
333:  beryllium, carbon, tin and lead targets were taken. Performance of the calorimeter 
334:  was studied using several observed physics processes: quasielastic and inelastic
335:   neutral pion photoproduction, Compton scattering and pair production.
336: 
337:   First, we consider Compton scattering which provides four constraints of the 
338:   reaction  kinematics and allows to study energy and space resolutions of the 
339:   detector however in limited range of small angles for the central PWO region 
340:   of the calorimeter. In Fig.~\ref{fig:p15} three 
341:   distributions of ratio of observed total energy in the calorimeter to the 
342:   incident energy of the tagged photon (~5.2 GeV) is plotted. The width of the 
343:   distribution of 1.5\% after calibration reduced to 1.1\% after the transverse 
344:   momentum correction ($P_t = 0$). If no calorimeter energy information is used but 
345:   only coordinate of the showers detected is considered the width became 1.7\%
346:   showing importance of energy resolution.
347: 
348: 
349: \begin{center}
350: \begin{figure}[!h]
351: %\includegraphics[angle=0,width=0.7\textwidth]{p15.eps}
352: \special{psfile=p15.eps
353: hoffset=-220
354: voffset=-400
355:  hscale=70
356:  vscale=70}
357: \special{psfile=abc.eps
358: hoffset=-170
359: voffset=-70
360:  hscale=70
361:  vscale=70}
362: 
363: \caption{Ratio of sum of electron and photon energies measured in the calorimeter 
364: and tagged $\gamma$ energy at $5.2 \pm 0.3 GeV$}
365: \label{fig:p15}
366: \end{figure}
367: \end{center}
368: 
369: \vspace{5.0cm}
370: 
371: 
372:   The Fig.~\ref{fig:p16} shows resolution in $\pi^0$ mass in the central (PWO)
373:   region of the calorimeter. The left part shows the distribution after the final 
374:   calibration on the nominal mass of the neutral pion (observed width of $2.3 MeV/c^2$)
375:   and on the right the peak of quasielastic neutral pion production after correction 
376:   on the primary tagged photon energy is presented. The observed width of $1.3 Mev/c^2$ 
377:   in latter case reflects angular resolution of the calorimeter. As the calorimeter 
378:   also detects many events of inelastic $\pi^0$ production we see a high mass tail of 
379:   the peak corresponding to this process: due to lower energy of such pions the 
380:   energy constrain shifts its mass to the higher value.
381:    We studied  $\pi^0$ mass resolution for transition region of the detector as well as 
382:     lead glass periphery. the results are shown in Fig.~\ref{fig:p17} and 
383:     Fig.~\ref{fig:p18}.
384: 
385: \clearpage
386: 
387: \begin{center}
388: \begin{figure}[!h]
389: %\includegraphics[angle=0,width=0.7\textwidth]{p16.eps}
390: \special{psfile=p16.eps
391: hoffset=-220
392: voffset=-400
393:  hscale=70
394:  vscale=70}
395: 
396: \special{psfile=ab.eps
397: hoffset=-170
398: voffset=-70
399:  hscale=70
400:  vscale=70}
401: 
402: 
403: \caption{$\pi^0$ mass resolution for the PWO array. Left:after final calibration 
404: on the nominal $\pi^0$ mass; Right: after correction on the tagged phot energy:
405: remaining width mostly due to coordinate resolution}
406: \label{fig:p16}
407: \end{figure}
408: 
409: \vspace{6.5cm}
410: 
411: \begin{figure}[!h]
412: %\includegraphics[angle=0,width=0.7\textwidth]{p17.eps}
413: \special{psfile=p17.eps
414: hoffset=-220
415: voffset=-400
416:  hscale=70
417:  vscale=70}
418: 
419: \special{psfile=ab.eps
420: hoffset=-170
421: voffset=-70
422:  hscale=70
423:  vscale=70}
424: 
425: 
426: \caption{$\pi^0$ mass resolution for the PWO-Lead Glass border. Left:after final calibration 
427: on the nominal $\pi^0$ mass; Right: after correction on the tagged photon energy:
428: remaining width mostly due to coordinate resolution}
429: \label{fig:p17}
430: \end{figure} 
431: %\end{center}
432: 
433: \vspace{6.5cm}
434: 
435: %\begin{center}
436: \begin{figure}[!h]
437: %\includegraphics[angle=0,width=0.7\textwidth]{p18.eps}
438: \special{psfile=p18.eps
439: hoffset=-220
440: voffset=-400
441:  hscale=70
442:  vscale=70}
443: 
444: \special{psfile=ab.eps
445: hoffset=-170
446: voffset=-70
447:  hscale=70
448:  vscale=70}
449: 
450: \caption{$\pi^0$ mass resolution for the lead glass array. Left:after final calibration 
451: on the nominal $\pi^0$ mass; Right: after correction on the tagged phot energy:
452: remaining width mostly due to coordinate resolution}
453: \label{fig:p18}
454: \end{figure} 
455: \end{center}
456: 
457: \clearpage
458: 
459: \section{Conclusion}
460: 
461:      Resolution is decreasing from $2.6 MeV/c^2$ on the border 
462:     to $4.5 MeV/c^2$ in the lead glass. Correction on the
463:     primary energy significantly improve the resolution, at the same time we see 
464:     increase of the tail of the inelastic production as detection angles are increasing.
465:     
466:     The success of the experiment is determined how well the low angle pion production 
467:     is measured. In the  Fig.~\ref{fig:p19} pion angular distributions for quasielastic 
468:     (corrected) neutral pion production presented for Carbon and Lead exposures. 
469:     Clearly Primakoff production peak is seen for both data sets. This shows good 
470:     calorimeter performance which should be adequate for the precision measurement of 
471:     the $\pi^0$  lifetime.  
472: 
473:  The high precision hybrid electromagnetic calorimeter (HYCAL) was designed, 
474:  constructed and run in physics experiment to measure lifetime of the neutral 
475:  pion via Primakoff effect. The measured characteristics of the detector fully 
476:  correspond to the design parameters. It allowed collecting a rich high quality 
477:  data sets to extract $\pi^0$ lifetime. The preliminary results are expected 
478:  in the end of this summer. Authors thank all PrimEx collaboration for excellent
479:  work of design, construction, running and data analysis of the experiment. 
480:  Stable performance of the CEBAF accelerator is gratefully  acknowledged. 
481:  The work was supported by the US NSF grant (PHY-0079840) and RFBR grant 
482:  (04-02-17466).
483: 
484: %\clearpage
485: 
486: \doingARLO[\bibliographystyle{aipproc}]
487:           {\ifthenelse{\equal{\AIPcitestyleselect}{num}}
488:              {\bibliographystyle{arlonum}}
489:              {\bibliographystyle{arlobib}}
490:           }
491: \bibliography{sample}
492: \begin{thebibliography}{sample}
493: 
494: \bibitem{prim_prop}
495: Primex Proposal
496: (http://www.jlab.org/primex/primex\_notes/PR99-014.ps) \\
497: Primex Collaboration,  December 17, 1998\\
498: \bibitem{prim_cdr}
499: Primex Conceptual Design Report
500: (http://www.jlab.org/primex/primex\_notes/PrimEx\_CDR.ps) \\
501: Primex Collaboration,  March 3, 2000\\
502: \bibitem{ashot2004}
503: High Performance PbWO4 Hybrid Calorimeter at Jefferson Lab \\
504: A. Gasparian, Proceedings to Calor-2004, March 30 \\
505: \\
506: \bibitem{prim_lms}
507: LED Based Light Monitoring System for the PrimEx Experiment at Jefferson Lab
508: (Proceedings Contribution to Calor-2002)
509: (http://www.jlab.org/primex/primex\_lmc\_c.ps) \\
510: Samuel Danagulian, 2002\\
511: \end{thebibliography}
512: 
513: 
514: \end{document}
515: 
516: