physics0702103/Proc.tex
1: % Template article for preprint document class `elsart'
2: % SP 2001/01/05
3: 
4: \documentclass[twocolumn]{elsart}
5: 
6: % Use the option doublespacing or reviewcopy to obtain double line spacing
7: % \documentclass[doublespacing]{elsart}
8: 
9: % if you use PostScript figures in your article
10: % use the graphics package for simple commands
11: \usepackage{graphics}
12: % or use the graphicx package for more complicated commands
13: % \usepackage{graphicx}
14: % or use the epsfig package if you prefer to use the old commands
15: % \usepackage{epsfig}
16: 
17: % The amssymb package provides various useful mathematical symbols
18: \usepackage{amssymb}
19: 
20: \begin{document}
21: 
22: \begin{frontmatter}
23: 
24: % Title, authors and addresses
25: 
26: % use the thanksref command within \title, \author or \address for footnotes;
27: % use the corauthref command within \author for corresponding author footnotes;
28: % use the ead command for the email address,
29: % and the form \ead[url] for the home page:
30: % \title{Title\thanksref{label1}}
31: % \thanks[label1]{}
32: % \author{Name\corauthref{cor1}\thanksref{label2}}
33: % \ead{email address}
34: % \ead[url]{home page}
35: % \thanks[label2]{}
36: % \corauth[cor1]{}
37: % \address{Address\thanksref{label3}}
38: % \thanks[label3]{}
39: 
40: \title{LHCb Level-0 Trigger Detectors}
41: 
42: % use optional labels to link authors explicitly to addresses:
43: % \author[label1,label2]{}
44: % \address[label1]{}
45: % \address[label2]{}
46: 
47: \author{A.~Sarti\corauthref{cor}}
48: 
49: \corauth[cor]{Corresponding author. Address: asarti@lnf.infn.it}
50: 
51: \address{INFN-Laboratori Nazionali di Frascati, Via E.Fermi, 40, 44100, Frascati, Italy}
52: 
53: \begin{abstract}
54: % Text of abstract
55: The calorimeter and muon systems are essential components 
56: to provide a trigger for the LHCb experiment.  The calorimeter system
57: comprises a scintillating pad detector and pre-shower, followed 
58: by electromagnetic and hadronic calorimeters. The 
59: calorimeter system allows photons, electrons and hadrons to be 
60: identified, and their energy to be measured. The muon system consists 
61: of five measuring stations equipped with Multi-Wire Proportional
62: Chambers (MWPCs) and triple-Gas Electron Multiplier (GEM) 
63: detectors, separated by iron 
64: filters. It allows the muons identification and transverse momentum 
65: measurement. The status of the two systems and their 
66: expected performance is presented.
67: \end{abstract}
68: 
69: \begin{keyword}
70: % keywords here, in the form: keyword \sep keyword
71: LHCb \sep Calorimeter \sep MWPC \sep GEM \sep Level-0 Trigger
72: % PACS codes here, in the form: \PACS code \sep code
73: \PACS 29.40.Vj \sep 29.40.Cs \sep 29.40.Gx
74: \end{keyword}
75: \end{frontmatter}
76: 
77: % main text
78: \section{Introduction}
79: \label{sec:intro}
80: 
81: The LHCb experiment is dedicated 
82: to the study of the decays of beauty hadrons
83: produced at the LHC. Precision measurements
84: of CP violation and rare decays in the 
85: $B$ meson systems, which are the main LHCb goals, can be achieved
86: only with a very well designed and efficient trigger\cite{bib:trigger}.\\
87: A key role in the trigger is played by the Level-0 (L0)
88: hardware step that reduces the event rate from 40MHz to
89: 1MHz using the input from the VELO\cite{bib:VELO} detector, the calorimeter
90: system\cite{bib:calotdr} and the muon system \cite{bib:muontdr}.
91: Design performances have been optimized 
92: in order to allow a fast reconstruction of high 
93: transverse energy ($E_T$, CALO system)
94: or high transverse momentum ($P_T$, MUON system) candidates
95: needed by the L0 decision unit (L0DU).
96: 
97: \section{Calorimeter system}
98: \label{sec:Calo}
99: 
100: The CALO system\cite{bib:calotdr} is made of a Scintillating
101: Pad Detector (SPD), followed by a Pre-Shower (PS)
102: in front of the Electromagnetic CALorimeter (ECAL) and
103: the Hadronic CALorimeter (HCAL).\\
104: The active elements
105: are scintillating tiles, read out via wave-length shifting fibres 
106: to photo-multipliers.  The scintillator is interleaved with lead for 
107: the electromagnetic calorimeter in a Shashlik construction, while for 
108: the hadronic calorimeter it is interleaved with steel tiles.\\
109: All these subdetectors are characterised by a pseudo-projective 
110: geometry achieved using a variable detector module granularity.
111: 
112: \subsection{Scintillating pad detector and pre-shower}
113: \label{sec:SPD-PS}
114: 
115: The SPD and PS detectors are used to distinguish
116: electrons from pions and photons (SPD), photons from
117: Minimum Ionizing Particles and to veto busy events
118: with a very high charged multiplicity (SPD).\\
119: The SPD/PS system is made from a lead converter plate 
120: (14mm thick) that is  sandwiched between two layers of 
121: scintillator pads (15mm thick).
122: The light collected is read from a Multi-Anode
123: PhotoMulTiplier (MAPMT) and sent to a Front-End card
124: (VFE).
125: 
126: \subsection{Electromagnetic calorimeter}
127: \label{sec:ECAL}
128: %==============================================
129: \begin{figure}[htbp]
130: \begin{center}
131: \resizebox{6.5cm}{!}{%
132: \includegraphics{fig5.eps}
133: }
134: \caption{ECAL module relative energy resolution, measured with
135: a 50GeV electron beam.}
136: \label{fig:energy-reso}
137: \end{center}
138: \end{figure}
139: %==============================================
140: The electromagnetic calorimeter is used to measure
141: the electron, photon and pion $E_T$. It provides
142: particle identification (PID) and reconstruction
143: information for the particles used in offline analysis.\\
144: It consists of nearly 3k Shashlik modules, for
145: a total of 6k detector cells,
146: that are read using WaveLenght Shifting (WLS) fibers from
147: KURARAY. Each module is positioned on the ECAL wall 
148: with $\pm$0.5mm ($x,y$) and $\pm$2mm ($z$) precision.\\ 
149: In order to achieve the design relative energy
150: resolution ($\sigma(E)/E = 10\% / \sqrt{E} \oplus 1.5\%$, 
151: with $E$ in GeV), a sampling structure of 2mm lead sheets
152: interspersed with 4mm thick scintillator plates has been used:
153: test beam results, using 50GeV electrons, are shown in
154: Fig.\ref{fig:energy-reso} (the achieved $\sigma(E)/E$ is 
155: $(9.4\pm0.2)\% / \sqrt{E} \oplus (0.83\pm0.02)\% \oplus (0.145\pm0.013)/E$, 
156: with $E$ in GeV).\\
157: Each module light yield is measured to be nearly 
158: 3000 ph.e./GeV.
159: Cell dimensions are varying in the range
160: 4$\times$4cm$^2$ to 12$\times$12cm$^2$.
161: The ECAL depth accounts for 25 electromagnetic radiation
162: lengths ($X_0$) and 1.1 hadronic interaction lengths
163: ($\lambda$).  
164: 
165: 
166: \subsection{Hadronic calorimeter}
167: \label{sec:HCAL}
168: 
169: The hadronic calorimeter is an iron-scintillator
170: tile calorimeter, composed of 52 modules
171: (1468 detector cells) with
172: variable granularity: the cell dimensions
173: vary from 13$\times$13cm$^2$ to 26$\times$26cm$^2$.\\
174: It is used to measure the $E_T$ of hadrons, and to provide
175: them to the offline analysis.
176: The HCAL depth accounts for 5.6 $\lambda$:
177: each module is read using WLS fibers and PMTs.\\
178: HCAL modules have been tested with a 30GeV electron
179: beam: the signal pulse is well contained in the 
180: 25ns bunch-crossing window. The energy resolution
181: achieved matches the design value 
182: ($\sigma(E)/E = 80\% / \sqrt{E} \oplus 10\%$, 
183: with $E$ in GeV) while
184: the achieved tile-to-tile spread is less than 5\%.\\
185: The HCAL wall has been assembled achieving 
186: a module-positioning precision of the order of
187: 0.5mm ($x,y$ plane and $y$ coordinate) and 1.5mm ($y,z$ lateral
188: plane). 
189: 
190: \section{Muon system}
191: \label{sec:Muon}
192: 
193: The LHCb muon system \cite{bib:muontdr}
194: is composed of five tracking stations, each subdivided in 
195: four concentric regions, which comprise 1368 MWPCs
196: and 24 triple GEM detectors.
197: The muon detector is required to have a high detection efficiency and
198: a good spatial and time resolution.\\
199: The geometry is projective: the layout 
200: has been optimized by choosing an $x,y$ granularity 
201: that added a contribution to the $P_T$ resolution 
202: nearly equal to that from the multiple
203: scattering.
204: The final layout is composed of 20 different pad sizes
205: (from 6.3$\times$31mm to 250$\times$310mm) resulting in 120k
206: logical channels.\\
207: 
208: \subsection{Triple GEM detectors}
209: \label{sec:GEM}
210: 
211: Triple GEM detectors\cite{bib:GEM} are going to be used only in the 
212: innermost region of the first station,
213: where the particle rate is expected to be the highest.\\
214: Those chambers are characterised by a high
215: rate capability, a high station efficiency 
216: (greater than 96\% in 20ns time window)
217: and a low cluster size (less than 1.2).
218: The achieved time resolution is 3ns when using 
219: an Ar/CO$_2$/CF$_4$ gas mixture of 45\%/15\%/40\%.
220: %a gas mixture composed by Ar/CO$_2$/CF$_4$ (45/15/40).
221: 
222: \subsection{MWPC}
223: \label{sec:MWPC}
224: 
225: %
226: %==============================================
227: \begin{figure}[!t]
228: \begin{center}
229: \resizebox{6.5cm}{!}{%
230: \includegraphics{Fig3.eps}
231: }
232: \caption{Efficiency (left scale and open circles) and pad-cluster size 
233: (right scale and solid circles) of a double-gap
234:  MWPC as a function of the high voltage (HV). The working region (WR)
235: is shown. Curves are drawn to guide the eye.}
236: \label{fig:plateau}
237: \end{center}
238: \end{figure}
239: %==============================================
240: %
241: The MWPCs  used in the muon system
242: are composed of double gas gaps that
243: are further logically OR-ed:
244: this will ensure a high hit detection efficiency and enhance the
245: detector robustness.\\
246: In order to meet the performance required for triggering and for physics
247: analysis, each double-gap should have an
248: efficiency $\geq 95$\%, within a 20ns time window, 
249: a cluster size $\leq 1.1$, as well as good ageing properties. 
250: These performances were measured, using a MIP test beam, 
251: as a function of the high voltage (HV) applied to the wires,
252: using an Ar/CO$_2$/CF$_4$ gas mixture of 40\%/50\%/10\%.
253: The results reported in Fig.\ref{fig:plateau}
254: show that the above conditions are satisfied for 
255: $2530 \leq \mathrm{HV} \leq 2700$V.\\
256: MWPCs are read out with a custom radiation hard chip (named
257: CARIOCA) 
258: that works as an amplifier, shaper and discriminator
259: characterised by a 10ns peak time. 
260: Chambers installation is currently starting: the expected
261: positioning precision is $\pm$1mm.
262: 
263: \section{L0 trigger}
264: 
265: The L0 hardware trigger\cite{bib:trigger} is fully synchronous, 
266: it has a fixed 
267: latency (4$\mu$s) and reduces the 40MHz interaction rate to
268: 1MHz.  The L0 Decision Unit (L0DU) takes as input: (from the CALO)
269: the highest $E_T$ candidate for each type (e, $\gamma$, $\pi^0$),
270: the total measured energy, the charged multiplicity
271: and (from the MUON) the two highest $P_T$ candidates per quadrant.
272: An efficiency of 30-50\% is achieved for the hadronic channels
273: (accounting for about 700kHz bandwidth) while
274: the muon channels are selected with 90\% efficiency.
275: 
276: \section{Conclusion}
277: 
278: The LHCb CALO and MUON systems 
279: are currently under installation and are going
280: to be ready for the data taking start in July 2007.
281: The calorimeter construction is now almost completed, and more than 
282: half of the required muon chambers have been produced.  
283: The muon filters are already in place while the support
284: wall is being built. 
285: Test beam data showed that the
286: design values have been achieved: detectors timing and 
287: resolution performances are very good.
288: The L0 hardware trigger design has been finalized:
289: the obtained efficiencies for hadronic, muonic and
290: radiative channels are expected to be 30--50\%, 90\% and 70\% 
291: respectively.
292: 
293: \begin{thebibliography}{00}
294: 
295: \bibitem{bib:trigger} A.\ Barczyk, these proceedings.
296: 
297: \bibitem{bib:VELO} J.J.\ Van Hunen, these proceedings.
298: 
299: \bibitem{bib:calotdr} LHCb Collaboration, 
300: ``LHCb Calorimeters Technical Design Report'', 
301: CERN/LHCC 2000-036 (2000).
302: 
303: %
304: %==========1===========
305: %
306: \bibitem{bib:muontdr} LHCb Collaboration, 
307: ``LHCb Muon System Technical Design Report'', 
308: CERN/LHCC 2001-010 (2001) and 
309: ``Addendum to the Muon System Technical Design Report'', 
310: CERN/LHCC 2003-002 (2003).
311: 
312: \bibitem{bib:GEM} M.\ Alfonsi et al., ``The Triple-GEM detector 
313: for the M1R1 muon station at LHCb'', N14-182, 2005 IEEE NSS 
314: Conference, Puerto Rico
315: 
316: \end{thebibliography}
317: 
318: \end{document}
319: 
320: